Skip to content
OpenCDD
V_INv1rev 22015-12-21

input voltage for line regulation

0112/2///61360_4#AFD149

range of input voltage for line regulation measurement, at the two ends of which the input voltage is measured

Used by classes
1
property

Also appears in1#

Entities with the same name in other dictionaries:

Code
AFD149
Data type
LEVEL(MIN,MAX) OF REAL_MEASURE_TYPE
Unit
UAA296 UAA296
Used by classes (1)

All properties18#

Version
1
Revision
2
Preferred name
input voltage for line regulation
Short name
V_IN
Definition
range of input voltage for line regulation measurement, at the two ends of which the input voltage is measured
Note
The first item is to record the minimum input voltage value and the second is to record the maximum input voltage value used in the line regulation measurements.
Unit structure
V
Initial value
0112/2///62720#UAA296 UAA296
Published in
NON_DEPENDENT_P_DET
Status level
Standard
Version release date
2023-11-21
Revision release date
2015-12-21
Version initiation date
2023-11-21
Change request ID
C00050
MDC_P022
LEVEL(MIN,MAX) OF REAL_MEASURE_TYPE
MDC_P025_1
V_IN