v5rev 12018-03-20IEC 61987-1, 5.7.3.4
upper limiting value of process gauge pressure
0112/2///61987#ABB187
highest gauge process pressure to which the wetted parts of the equipment can be subjected without permanent impairment of operating characteristics
- Used by classes
- 5
- Code
ABB187- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAA323 UAA323
All properties29#
- Version
- 5
- Revision
- 1
- Preferred name
- upper limiting value of process gauge pressure
- Definition
- highest gauge process pressure to which the wetted parts of the equipment can be subjected without permanent impairment of operating characteristics
- Definition source
- IEC 61987-1, 5.7.3.4
- Definition class
- 0112/2///61987#ABA000Equipment for industrial-process automation
- Unit structure
- bar
- Initial value
- 0112/2///62720#UAA323 UAA323
- Responsible committee
- SC65E – IEC 61987
- Published in
- NON_DEPENDENT_P_DET
- Status level
- Standard
- Version release date
- 2018-03-28
- Revision release date
- 2018-03-20
- Version initiation date
- 2018-03-20
- Original definition date
- 2013-08-27
- Change request ID
- C00019
- C017
- C018
- C019
- MDC_P022
- REAL_MEASURE_TYPE