Skip to content
OpenCDD
v1rev 42013-10-16

long-term drift of zero or lower range-limit

0112/2///61987#ABB717

drift in zero or lower range-limit value monitored for 30 days with a constant input signal of 90% of span

Used by classes
6
property
Code
ABB717
Data type
REAL_MEASURE_TYPEmeasure
Unit
UAA000 UAA000
Used by classes (6)

All properties28#

Version
1
Revision
4
Preferred name
long-term drift of zero or lower range-limit
Definition
drift in zero or lower range-limit value monitored for 30 days with a constant input signal of 90% of span
Unit structure
%
Initial value
0112/2///62720#UAA000 UAA000
Responsible committee
SC65E – IEC 61987
Published in
NON_DEPENDENT_P_DET
Status level
Standard
Version release date
2018-03-28
Revision release date
2013-10-16
Version initiation date
2016-09-30
Original definition date
2013-08-27
Change request ID
C00004
C017
C018
C019
MDC_P022
REAL_MEASURE_TYPE