Skip to content
OpenCDD
v1rev 42013-10-16IEC 61298 and IEC 60770-2

measured error of mass flow

0112/2///61987#ABB721

largest positive or negative value of error of the average upscale or downscale value at each point of mass flow measurement expressed as an absolute value

Used by classes
2
property
Code
ABB721
Data type
REAL_MEASURE_TYPEmeasure
Unit
UAA607 UAA607
Used by classes (2)

All properties29#

Version
1
Revision
4
Preferred name
measured error of mass flow
Definition
largest positive or negative value of error of the average upscale or downscale value at each point of mass flow measurement expressed as an absolute value
Definition source
IEC 61298 and IEC 60770-2
Unit structure
kg/h
Initial value
0112/2///62720#UAA607 UAA607
Responsible committee
SC65E – IEC 61987
Published in
NON_DEPENDENT_P_DET
Status level
Standard
Version release date
2018-03-28
Revision release date
2013-10-16
Version initiation date
2016-09-30
Original definition date
2013-08-27
Change request ID
C00004
C017
C018
C019
MDC_P022
REAL_MEASURE_TYPE