v2rev 12018-03-20
calculated flow coefficient Kv
0112/2///61987#ABD548
calculation result for the flow coefficient Kv resulting from the given process conditions not taking into account the pressure loss of a pipe reduction at the inlet or outlet
- Used by classes
- 2
- Code
ABD548- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAA763 UAA763
All properties22#
- Version
- 2
- Revision
- 1
- Preferred name
- calculated flow coefficient Kv
- Definition
- calculation result for the flow coefficient Kv resulting from the given process conditions not taking into account the pressure loss of a pipe reduction at the inlet or outlet
- Definition class
- 0112/2///61987#ABA000Equipment for industrial-process automation
- Unit structure
- m³/h
- Initial value
- 0112/2///62720#UAA763 UAA763
- Published in
- NON_DEPENDENT_P_DET
- Status level
- Standard
- Version release date
- 2018-03-28
- Revision release date
- 2018-03-20
- Version initiation date
- 2018-03-20
- Original definition date
- 2013-09-02
- Change request ID
- C00004
- C017
- C018
- C019
- MDC_P022
- REAL_MEASURE_TYPE