Skip to content
OpenCDD
v1rev 12018-03-28IEC 61298-1, Ed. 2.0, 3.5

inaccuracy of volume

0112/2///61987#ABE839

for a volume measurement, the maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure

Used by classes
2
property
Code
ABE839
Data type
REAL_MEASURE_TYPEmeasure
Unit
UAA757 UAA757
Used by classes (2)

All properties26#

Version
1
Revision
1
Preferred name
inaccuracy of volume
Definition
for a volume measurement, the maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure
Definition source
IEC 61298-1, Ed. 2.0, 3.5
Unit structure
m³
Initial value
0112/2///62720#UAA757 UAA757
Responsible committee
SC65E
Publisher
IEC
Published in
IEC 61987
Published in
NON_DEPENDENT_P_DET
Status level
Standard
Version release date
2018-03-28
Revision release date
2018-03-28
Version initiation date
2018-03-28
Original definition date
2018-03-28
Change request ID
C00018
C017
C018
C019
MDC_P022
REAL_MEASURE_TYPE