v1rev 12018-03-28
maximum influence of volume flow rate on density
0112/2///61987#ABF583
change in output of a density measuring device caused by a change in volume flow rate with respect to reference conditions, expressed as the maximum error within the specified volume flow rate range
- Used by classes
- 1
- Code
ABF583- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAC812 UAC812
All properties23#
- Version
- 1
- Revision
- 1
- Preferred name
- maximum influence of volume flow rate on density
- Definition
- change in output of a density measuring device caused by a change in volume flow rate with respect to reference conditions, expressed as the maximum error within the specified volume flow rate range
- Definition class
- 0112/2///61987#ABA000Equipment for industrial-process automation
- Unit structure
- "(g/m³)/(m³/h)"
- Initial value
- 0112/2///62720#UAC812 UAC812
- Responsible committee
- SC65E – IEC 61987
- Published in
- NON_DEPENDENT_P_DET
- Status level
- Standard
- Version release date
- 2018-03-28
- Revision release date
- 2018-03-28
- Version initiation date
- 2018-03-28
- Original definition date
- 2018-03-28
- Change request ID
- C00018
- C017
- C018
- C019
- MDC_P022
- REAL_MEASURE_TYPE