Peak Valuev1rev 12025-02-24
peak value over upper range-limit of measurement
0112/2///61987#ABQ019
extrapolated maximum gas concentration upon overload
- Used by classes
- 1
- Code
ABQ019- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAD925 UAD925
All properties31#
- Version
- 1
- Revision
- 1
- Preferred name
- peak value over upper range-limit of measurement
- Synonymous name
- concentration of sensor overload
- Short name
- Peak Value
- Definition
- extrapolated maximum gas concentration upon overload
- Note
- overload is when the upper range-limit is exceeded
- Remark
- also used by Process Automation - Device Information Model (PA-DIM)
- Definition class
- 0112/2///61987#ABA000Equipment for industrial-process automation
- Unit structure
- ppm
- Initial value
- 0112/2///62720#UAD925 UAD925
- Responsible committee
- IEC/SC 65E
- Publisher
- IEC
- Published in
- IEC 61987
- Published in
- NON_DEPENDENT_P_DET
- Status level
- Standard
- Version release date
- 2025-02-24
- Revision release date
- 2025-02-24
- Version initiation date
- 2025-02-24
- Original definition date
- 2025-02-24
- Change request ID
- C00172
- C017
- C018
- C019
- MDC_P022
- REAL_MEASURE_TYPE