v1rev 32020-01-112.3.1.3 of IEC 60947-5-2:2007
blind zone
0112/2///62683#ACE252
zone between the sensing face of the sensor and the minimum operating distance where no object can be detected
- Used by classes
- 1
- Code
ACE252- Data type
- REAL_MEASURE_TYPEmeasure
- Unit
- UAA862 UAA862
All properties39#
- Version
- 1
- Revision
- 3
- Preferred name
- blind zone
- Definition
- zone between the sensing face of the sensor and the minimum operating distance where no object can be detected
- Definition source
- 2.3.1.3 of IEC 60947-5-2:2007
- Definition class
- 0112/2///62683#ACC012General technical data
- Unit structure
- mm
- Drawing reference
- NR2..3.1
- Initial value
- 0112/2///62720#UAA862 UAA862
- Responsible committee
- IEC 121A/WG 17
- Publisher
- IEC
- Published in
- IEC 62683DB
- Published in
- NON_DEPENDENT_P_DET
- Status level
- Standard
- Version release date
- 2023-11-23
- Revision release date
- 2020-01-11
- Version initiation date
- 2023-11-23
- Original definition date
- 2015-07-16
- Change request ID
- C00146
- C017
- C018
- C019
- MDC_P001_6
- 0112/2///62683#ACE252blind zone
- MDC_P008_2
- ACI505
- MDC_P022
- REAL_MEASURE_TYPE
- Source definition
- {0112/2///62720#UAA539,0112/2///62720#UAA841}
- MDC_P111
- {inch,milli‑inch}