Skip to content
OpenCDD
v1rev 12022-09-08D.3.5 of IEC 60947-5-1 ED 5

assured release distance

0112/2///62683#ACE269

distance from the sensing face beyond which the absence of the magnetic actuator is correctly detected under all specified environmental conditions and manufacturing tolerances

property
Code
ACE269
Data type
REAL_MEASURE_TYPEmeasure
Unit
UAA862 UAA862
Condition
0112/2///62683#ACE440

All properties40#

Version
1
Revision
1
Preferred name
assured release distance
Definition
distance from the sensing face beyond which the absence of the magnetic actuator is correctly detected under all specified environmental conditions and manufacturing tolerances
Definition source
D.3.5 of IEC 60947-5-1 ED 5
Unit structure
mm
Drawing reference
NR2..2.1
Value format
{0112/2///62683#ACE440}
Initial value
0112/2///62720#UAA862 UAA862
Responsible committee
IEC/TC 121
Publisher
IEC
Published in
IEC 62683DB
Published in
DEPENDENT_P_DET
Status level
Standard
Version release date
2022-09-08
Revision release date
2022-09-08
Version initiation date
2022-09-08
Original definition date
2022-09-08
Change request ID
C00107
C017
C018
C019
MDC_P022
REAL_MEASURE_TYPE
MDC_P025_1
sar
Source definition
{0112/2///62720#UAA539,0112/2///62720#UAA841}
MDC_P111
{inch,milli‑inch}