performance level
discrete level used to specify the ability of safety-related parts of control systems to perform a safety function under foreseeable conditions
- Terms
- 5
- Used by properties
- 1
Terms5#
ACH677PL aability of safety-related parts of control systems to perform a safety function with an average probability of dangerous failure per hour less than 10-4
ACH678PL bability of safety-related parts of control systems to perform a safety function with an average probability of dangerous failure per hour less than 10-5
ACH679PL cability of safety-related parts of control systems to perform a safety function with an average probability of dangerous failure per hour less than 3 x 10-6
ACH680PL dability of safety-related parts of control systems to perform a safety function with an average probability of dangerous failure per hour less than 10-6
ACH681PL eability of safety-related parts of control systems to perform a safety function with an average probability of dangerous failure per hour less than 10-7
All properties36#
- Version
- 1
- Revision
- 1
- Preferred name
- performance level
- Definition
- discrete level used to specify the ability of safety-related parts of control systems to perform a safety function under foreseeable conditions
- Definition source
- ISO 13849-1:2023, 3.1.5
- Remark
- Value list from ISO 13849-1:2023, Figure 12
- Applicable data type
- {PLA,PLB,PLC,PLD,PLE}
- Applicable unit
- {0112/2///62683#ACH677,0112/2///62683#ACH678,0112/2///62683#ACH679,0112/2///62683#ACH680,0112/2///62683#ACH681}
- Responsible committee
- IEC/TC 121
- Publisher
- IEC
- Status level
- Standard
- Version release date
- 2025-09-25
- Revision release date
- 2025-09-26
- Version initiation date
- 2025-09-26
- Original definition date
- 2025-09-26
- Change request ID
- C00094
- C017
- C018
- C019
- MDC_P001_12