I_der}v2rev 12024-07-10
current derating factor
0112/2///61360_4#ADA088
required minimum current derating factor of an electric-electronic or electromechanical component, for a specified ambient temperature higher than the rated temperature
- Used by classes
- 1
- Code
ADA088- Data type
- LEVEL(MIN) OF REAL_MEASURE_TYPE
- Unit
- UAA915 UAA915
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.
Metadata#
- Note
- The derating factor (< 1) indicates the required reduction of the maximum ocurring current ( (rated current) above the rated ambient temperature avoiding the overheating of the component. In such case, the thermal power loss corresponds to the value as if operating the component with rated current at rated ambient temperature.
- Remark
- replaces AAE905 dissipation derating factor
- Version
- 2
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61360-4
- Responsible committee
- IEC/SC 3D
- Change request
C00162- Dates
- Current version: 2024-07-10
- Current revision: 2024-07-10