I_der}v2rev 12024-07-10

current derating factor

0112/2///61360_4#ADA088

required minimum current derating factor of an electric-electronic or electromechanical component, for a specified ambient temperature higher than the rated temperature

Used by classes
1
property
Code
ADA088
Data type
LEVEL(MIN) OF REAL_MEASURE_TYPE
Unit
UAA915 UAA915
Used by classes (1)

Version history2#

  1. Current rev 01
    10 Jul 2024 · 14:45 UTC by BATCH 00001307
    View on cdd.iec.ch ↗
  2. superseded rev 01
    21 Dec 2017 · 12:45 UTC by BATCH 00001033
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.

Metadata#

Note
The derating factor (< 1) indicates the required reduction of the maximum ocurring current ( (rated current) above the rated ambient temperature avoiding the overheating of the component. In such case, the thermal power loss corresponds to the value as if operating the component with rated current at rated ambient temperature.
Remark
replaces AAE905 dissipation derating factor
Version
2
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61360-4
Responsible committee
IEC/SC 3D
Change request
C00162
Dates
  • Current version: 2024-07-10
  • Current revision: 2024-07-10