Skip to content
OpenCDD
v1rev 12013-07-04IEC 60079-10-2:2009

hazarduous dust area class types

0112/2///61360_4#AAF876

coded classification values of an area in which an explosive dust atmosphere is present, or may be expected to be present, in quantities such as to require special precautions for the construction, installation and use of electrical apparatus

Terms
3
value list

Terms3#

AAF810Zone 20

area in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently

AAF811Zone 21

area in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur, occasionally, in normal operation

AAF812Zone 22

area in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only

Metadata#

Source document
IEC 60079-10-2:2009
Version
1
Revision
1
Status
Standard
Change request
C00020
Dates
  • Current version: 2013-07-04
  • Current revision: 2013-07-04