Absolute performance for density
properties characterizing the accuracy of a density measurement, expressed in engineering units
Hierarchy#
Ancestors (top) → ABC058 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties15#
largest positive or negative value of error of the average upscale or downscale value at each point of density measurement expressed as an absolute value
equation from which the measured error of a device can be calculated
for a density measurement, the maximum positive and negative deviation from the specified characteristic curve observed in testing a device under specified conditions and by a specified procedure
absolute error of a device measuring density under reference conditions, when the input is at the lower range value
@number of accuracies for a subrange of density
algebraic difference between the extreme values obtained by a number of consecutive measurements of the output over a short period of time for the same value of the input under the same operating conditions, approaching from the same direction, for full range traverses of density
equation from which the non-repeatability of a device can be calculated
additional percentage error to be added to the measured error of a measured value
basis for stating an additional error for analog output
quality which characterizes the ability of a density measuring instrument to provide an indicated value close to a true value of the measurand under reference conditions
reference to block ABC070
reference to block ABC210
ABC912reference to Influence of external quantities for densityCLASS_REFERENCE_TYPE(0112/2///61987#ABC282)reference to block ABC282
reference to block ABC324
probability, generally expressed as a percentage, that the true value of a statistically estimated quantity falls within a pre-established interval about the estimated value
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- 15 ABC058.15
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (26 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC058
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Leistungsdaten für Dichte in absoluten Einheiten
- MDC_P004.en
- Absolute performance for density
- MDC_P004.fr
- Performance absolue pour la masse volumique
- MDC_P006.de
- Merkmale, die die Genauigkeit einer Dichtemessung, ausgedrückt in physikalischen Einheiten, kennzeichnen
- MDC_P006.en
- properties characterizing the accuracy of a density measurement, expressed in engineering units
- MDC_P006.fr
- propriétés caractérisant l'exactitude d'une mesure de masse volumique exprimée en unités techniques
- MDC_P009.en
- 15 ABC058.15
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB782,0112/2///61987#ABD535,0112/2///61987#ABB224,0112/2///61987#ABB741,0112/2///61987#ABB742,0112/2///61987#ABB770,0112/2///61987#ABB743,0112/2///61987#ABC700,0112/2///61987#ABB519,0112/2///61987#ABB774,0112/2///61987#ABB775,0112/2///61987#ABB776,0112/2///61987#ABC912,0112/2///61987#ABC840,0112/2///61987#ABC954}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.