Analog current input parameters
properties characterizing the configuration of the analog current input
Hierarchy#
Ancestors (top) → ABC085 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
classification of an analog input signal according to its information parameter
classification of a power source according to its function as an energy source or sink
behaviour of a power source set at the factory
current value to which the lower range end-value of a current input signal has been adjusted
current value to which the upper range end-value of a current input signal has been adjusted
minimum value that a current signal can assume and still exhibit linear behaviour
highest value that a current signal can assume and still exhibit linear behaviour
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
digital communication protocol superimposed on the analog input or output
@number of electrical terminals
reference to block ABC148
reference to block ABC176
reference to block ABC212
reference to block ABC213
reference to block ABC220
ABC865reference to Explosion protection parameters for intrinsic safetyCLASS_REFERENCE_TYPE(0112/2///61987#ABC235)reference to block ABC235
ABI463reference to Explosion protection parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABI462)reference to block ABI462
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00019
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2016-05-13
- C018.fr
- 2016-05-13
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC085
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Parameter des analogen Stromeingangs
- MDC_P004.en
- Analog current input parameters
- MDC_P004.fr
- Paramètres d'entrée de courant analogique
- MDC_P006.de
- Merkmale, die die Konfiguration eines analogen Stromeingangs kennzeichnen
- MDC_P006.en
- properties characterizing the configuration of the analog current input
- MDC_P006.fr
- propriétés caractérisant la configuration de l’entrée de courant analogique
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA367,0112/2///61987#ABA368,0112/2///61987#ABA369,0112/2///61987#ABA370,0112/2///61987#ABA371,0112/2///61987#ABA373,0112/2///61987#ABA374,0112/2///61987#ABC806,0112/2///61987#ABA997,0112/2///61987#ABC843,0112/2///61987#ABC842,0112/2///61987#ABA390,0112/2///61987#ABC865,0112/2///61987#ABI463,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.