Analog current output parameters
properties characterizing the configuration of the analog current output
Hierarchy#
Ancestors (top) → ABC091 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties22#
classification of a power source according to its function as an energy source or sink
behaviour of a power source set at the factory
minimum value that a current signal can assume and still exhibit linear behaviour
highest value that a current signal can assume and still exhibit linear behaviour
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
classification of a current output according to the range end-values of the information parameter
current value to which the lower range end-value of a current output signal has been adjusted
current value to which the upper range end-value of a current output signal has been adjusted
smallest detectable increment between two signal values
digital communication protocol superimposed on the analog input or output
@number of electrical terminals
reference to block ABC148
reference to block ABC176
reference to block ABC212
reference to block ABC213
reference to block ABC220
ABC865reference to Explosion protection parameters for intrinsic safetyCLASS_REFERENCE_TYPE(0112/2///61987#ABC235)reference to block ABC235
ABI463reference to Explosion protection parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABI462)reference to block ABI462
provision of a lead breakage and short circuit monitoring function by the device or measuring assembly
setting of line fault monitoring
reference to block ABP027
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00128- Dates
- Original: 2017-12-07
- Current version: 2023-01-23
- Current revision: 2023-01-23
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (28 keys from source .xls) — click to expand
- C002
- C00128
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2016-05-13
- C018.fr
- 2016-05-13
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC091
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-01-23
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2023-01-23
- MDC_P003_3
- 2023-01-23
- MDC_P004.de
- Parameter des analogen Stromausgangs
- MDC_P004.en
- Analog current output parameters
- MDC_P004.fr
- Paramètres de sortie de courant analogique
- MDC_P006.de
- Merkmale, die die Konfiguration eines analogen Stromausgangs kennzeichnen
- MDC_P006.en
- properties characterizing the configuration of the analog current output
- MDC_P006.fr
- propriétés caractérisant la configuration de la sortie de courant analogique
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABA435,0112/2///61987#ABA368,0112/2///61987#ABA369,0112/2///61987#ABA438,0112/2///61987#ABA442,0112/2///61987#ABA373,0112/2///61987#ABA374,0112/2///61987#ABP077,0112/2///61987#ABP078,0112/2///61987#ABC806,0112/2///61987#ABA997,0112/2///61987#ABA444,0112/2///61987#ABP231,0112/2///61987#ABC843,0112/2///61987#ABC842,0112/2///61987#ABA390,0112/2///61987#ABC865,0112/2///61987#ABI463,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
- MDC_P019
- false