Assigned actual volume flow range
properties characterizing a range configured for actual volumetric flow
Hierarchy#
Ancestors (top) → ABC105 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties4#
actual volumetric flow value assigned to the lower range end-value of the input or output signal
actual volumetric flow value assigned to the upper range end-value of the input or output signal
difference between the upper and lower range value of actual volume flow to which an actual volume flow measurement instrument is adjusted
difference between the upper and lower range value of actual volume flow to which an actual volume flow measurement instrument is adjusted and calibrated
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- 13 ABC105.13
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (26 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC105
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Eingestellter Bereich für Betriebsvolumendurchfluss
- MDC_P004.en
- Assigned actual volume flow range
- MDC_P004.fr
- Étendue de débit volumique réel affectée
- MDC_P006.de
- Merkmale, die den für Betriebsvolumendurchfluss konfigurierten Bereich kennzeichnen
- MDC_P006.en
- properties characterizing a range configured for actual volumetric flow
- MDC_P006.fr
- propriétés caractérisant une étendue configurée pour le débit volumétrique réel
- MDC_P009.en
- 13 ABC105.13
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA348,0112/2///61987#ABA350,0112/2///61987#ABB564,0112/2///61987#ABB565}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.