Binary transistor/triac output
properties characterizing a binary transistor/triac output
Hierarchy#
Ancestors (top) → ABC141 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties32#
classification of a power source according to its function as an energy source or sink
behaviour of a power source set at the factory
@number of galvanic isolations
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
@number of signal functions
time delay between the passing of a limit value and the resulting switching action
nominal signal voltage level for a binary logic state "1"
maximum permissible switching frequency for which a device is designed to operate
maximum permissible switching frequency for which a device is designed to operate
maximum value of an input or output voltage signal for the logical state "1"
minimum value of an input or output voltage signal for the logical state "1"
maximum value of an input or output voltage signal for the logical state "0"
minimum value of an input or output voltage signal for the logical state "0"
@number of electrical terminals
standard on which statements on a particular property refer
reference to block ABC148
reference to block ABC220
ABC865reference to Explosion protection parameters for intrinsic safetyCLASS_REFERENCE_TYPE(0112/2///61987#ABC235)reference to block ABC235
reference to block ABC261
reference to block ABC594
classification of a deadband according to its adjustability
classification of a means of overvoltage protection according to its electrical and mechanical construction
ABI463reference to Explosion protection parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABI462)reference to block ABI462
cardinality property for AC rating for external power
cardinality property for DC rating for external power
maximum leakage current which can flow when the input or output is in the zero state
greatest time delay between triggering and the resulting switching on action
greatest time delay between triggering and the resulting switching off action
reference to block ABP033
reference to block ABC066
reference to block ABC179
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 7
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00128- Dates
- Original: 2017-12-07
- Current version: 2023-01-23
- Current revision: 2023-01-23
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00128
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 1
- C018.de
- 2021-11-22
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC141
- MDC_P002_1
- 7
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-01-23
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2023-01-23
- MDC_P003_3
- 2023-01-23
- MDC_P004.de
- Binärer Transistor-/Triacausgang
- MDC_P004.en
- Binary transistor/triac output
- MDC_P006.de
- Merkmale, die einen binären Transistor-/Triacausgang kennzeichnen
- MDC_P006.en
- properties characterizing a binary transistor/triac output
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABB513,0112/2///61987#ABA610,0112/2///61987#ABA412,0112/2///61987#ABD220,0112/2///61987#ABA943,0112/2///61987#ABA942,0112/2///61987#ABA941,0112/2///61987#ABA940,0112/2///61987#ABP128,0112/2///61987#ABA368,0112/2///61987#ABA369,0112/2///61987#ABA629,0112/2///61987#ABP079,0112/2///61987#ABP281,0112/2///61987#ABP081,0112/2///61987#ABP282,0112/2///61987#ABH369,0112/2///61987#ABA457,0112/2///61987#ABP142,0112/2///61987#ABP141,0112/2///61987#ABA629,0112/2///61987#ABH398,0112/2///61987#ABP237,0112/2///61987#ABA387,0112/2///61987#ABC891,0112/2///61987#ABA390,0112/2///61987#ABC865,0112/2///61987#ABI463,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
- MDC_P019
- false
Version history8#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.