Binary input
properties characterizing an auxiliary binary input
Hierarchy#
Ancestors (top) → ABC142 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties29#
classification of a power source according to its function as an energy source or sink
behaviour of a power source set at the factory
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
@number of signal functions
minimum permissible ratio of the pulse duration to the pulse period of a periodic pulse train
nominal signal voltage level for a binary logic state "1"
maximum permissible switching frequency for which a device is designed to operate
lowest upper range end-value to which a frequency output can be adjusted
highest upper range end-value to which a frequency output can be adjusted
maximum value of an input or output voltage signal for the logical state "1"
minimum value of an input or output voltage signal for the logical state "1"
maximum value of an input or output voltage signal for the logical state "0"
minimum value of an input or output voltage signal for the logical state "0"
@number of electrical terminals
for a binary signal, the permissible minimum duration of the signal with the logic value "0"
maximum permissible ratio of the pulse duration to the pulse period of a periodic pulse train
standard on which statements on a particular property refer
for a binary signal, the permissible minimum duration of the signal with the logic value "0"
for a binary signal, the permissible minimum duration of the signal with the logic value "1"
for a binary signal, the permissible maximum duration of the signal with the logic value "1"
lowest permissible switching frequency for which a device is designed to operate
reference to block ABC148
reference to block ABC212
reference to block ABC213
reference to block ABC220
ABC865reference to Explosion protection parameters for intrinsic safetyCLASS_REFERENCE_TYPE(0112/2///61987#ABC235)reference to block ABC235
reference to block ABC594
ABI463reference to Explosion protection parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABI462)reference to block ABI462
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- 2 ABC142.2
- Version
- 2
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (26 keys from source .xls) — click to expand
- C002
- C00019
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2016-05-13
- C018.fr
- 2016-05-13
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC142
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Binäreingang
- MDC_P004.en
- Binary input
- MDC_P004.fr
- Entrée binaire
- MDC_P006.de
- Merkmale, die einen binären Hilfseingang kennzeichnen
- MDC_P006.en
- properties characterizing an auxiliary binary input
- MDC_P006.fr
- propriétés caractérisant une entrée binaire auxiliaire
- MDC_P009.en
- 2 ABC142.2
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB513,0112/2///61987#ABA412,0112/2///61987#ABD220,0112/2///61987#ABA610,0112/2///61987#ABA943,0112/2///61987#ABA942,0112/2///61987#ABA941,0112/2///61987#ABA940,0112/2///61987#ABB516,0112/2///61987#ABB517,0112/2///61987#ABB157,0112/2///61987#ABB515,0112/2///61987#ABA414,0112/2///61987#ABB158,0112/2///61987#ABA630,0112/2///61987#ABA934,0112/2///61987#ABB756,0112/2///61987#ABA629,0112/2///61987#ABA368,0112/2///61987#ABA369,0112/2///61987#ABC843,0112/2///61987#ABC842,0112/2///61987#ABA390,0112/2///61987#ABC865,0112/2///61987#ABI463,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.