Binary relay output
properties characterizing a binary relay contact output
Hierarchy#
Ancestors (top) → ABC144 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties26#
@number of galvanic isolations
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
@number of signal functions
voltage available at a contact for powering the connected device
time delay between the passing of a limit value and the resulting switching action
number of switching events for which a relay was designed
number of load cycles before failure of a switching element when the load remains within specifications
maximum permissible switching frequency for which a device is designed to operate
@number of electrical terminals
classification of a contact according to the mechanism by which it makes or breaks the switch circuit
standard on which statements on a particular property refer
reference to block ABC148
reference to block ABC220
reference to block ABC223
ABC865reference to Explosion protection parameters for intrinsic safetyCLASS_REFERENCE_TYPE(0112/2///61987#ABC235)reference to block ABC235
reference to block ABC261
reference to block ABC594
classification of a deadband according to its adjustability
ABI463reference to Explosion protection parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABI462)reference to block ABI462
cardinality property for AC rating for external power
cardinality property for DC rating for external power
greatest time delay between triggering and the resulting switching on action
greatest time delay between triggering and the resulting switching off action
reference to block ABC066
reference to block ABC179
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 7
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00128- Dates
- Original: 2017-12-07
- Current version: 2023-01-23
- Current revision: 2023-01-23
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (23 keys from source .xls) — click to expand
- C002
- C00128
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 1
- C018.de
- 2021-11-22
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC144
- MDC_P002_1
- 7
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-01-23
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2023-01-23
- MDC_P003_3
- 2023-01-23
- MDC_P004.de
- Binärer Relaisausgang
- MDC_P004.en
- Binary relay output
- MDC_P006.de
- Merkmale, die einen binären Relaisausgang kennzeichnen
- MDC_P006.en
- properties characterizing a binary relay contact output
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABB513,0112/2///61987#ABA412,0112/2///61987#ABD220,0112/2///61987#ABA454,0112/2///61987#ABB152,0112/2///61987#ABC853,0112/2///61987#ABP079,0112/2///61987#ABP281,0112/2///61987#ABP081,0112/2///61987#ABP282,0112/2///61987#ABH369,0112/2///61987#ABA457,0112/2///61987#ABP142,0112/2///61987#ABP141,0112/2///61987#ABA629,0112/2///61987#ABA608,0112/2///61987#ABA458,0112/2///61987#ABA387,0112/2///61987#ABC891,0112/2///61987#ABA390,0112/2///61987#ABC865,0112/2///61987#ABI463,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
- MDC_P019
- false
Version history8#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.