Clamp-on ultrasonic flowmeter
properties characterizing the sensor assembly of a clamp-on-type ultrasonic flowmeter
Hierarchy#
Ancestors (top) → ABC157 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties18#
degree of ingress protection offered by a housing or enclosure
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
length of a cable connecting two devices
maximum nominal diameter that can be used for operation of the device within the specified accuracy limits
minimum nominal diameter of the pipeline that can be used for operation of the device within the specified accuracy limits
classification of a sensor assembly of an ultrasonic flowmeter according to the number of beams in use
standard to which a statement on an enclosure protection type or class refers
classification of a sensor assembly of an ultrasonic flowmeter according to its mounting arrangement
classification of a sensor assembly of an ultrasonic flowmeter according to the number of beam traverses in use
number of sensor (transmitter/receiver) heads supplied with the sensor assembly
means by which a device is fastened to a pipe or wall
material of an adapter to adjust surfaces of different shapes of transducer and pipe
fluid by which a sensor makes acoustic contact with the pipe
horizontal distance between the front and back of a device, when standing in its normal position of use
horizontal distance between the left-hand and right-hand extremes of a device, when standing in its normal position of use
vertical distance between the top and bottom of the device when standing in its normal position of use
reference to block ABC352
reference to block ABC359
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- 17 ABC157.17
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (26 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC157
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Aufschnall-Ultraschalldurchflussmesser
- MDC_P004.en
- Clamp-on ultrasonic flowmeter
- MDC_P004.fr
- Débitmètre à ultrasons fixé par clamp
- MDC_P006.de
- Merkmale, die die Sensoranordnung eines Aufschnall-Ultraschalldurchflussmessers kennzeichnen
- MDC_P006.en
- properties characterizing the sensor assembly of a clamp-on-type ultrasonic flowmeter
- MDC_P006.fr
- propriétés caractérisant l’ensemble de capteur d’un débitmètre à ultrasons fixé par clamp
- MDC_P009.en
- 17 ABC157.17
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB488,0112/2///61987#ABB486,0112/2///61987#ABB130,0112/2///61987#ABB487,0112/2///61987#ABB492,0112/2///61987#ABB493,0112/2///61987#ABB494,0112/2///61987#ABB495,0112/2///61987#ABB496,0112/2///61987#ABB497,0112/2///61987#ABB106,0112/2///61987#ABB105,0112/2///61987#ABB007,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABC982,0112/2///61987#ABC989}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.