Connection compartment
properties characterizing a connection compartment
Hierarchy#
Ancestors (top) → ABC171 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties17#
classification of a housing according to its general protective purpose
classification of a connection compartment according to its use
classification of a terminal according to its mechanical design
material of which a terminal connecting piece is made
degree of ingress protection offered by a housing or enclosure
number of terminals for the connection of single wires within a connection compartment
classification of a fixation of a device or component according to the method of mounting
smallest core cross-section expressed as an area that can be accommodated by a terminal
smallest core cross-section expressed as AWG/kcmil that can be accommodated by a terminal
largest core cross-section expressed in AWG/kcmil that can be accommodated by a terminal
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere
material of which a connection compartment is made
largest core cross-section expressed as an area that can be accommodated by a terminal
standard to which a statement on an enclosure protection type or class refers
design of a device or a device component mounting classified by the type of surface on/to which it will be mounted
angle of a fastening measure with respect to the vertical
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC171
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Anschlussgehäuse
- MDC_P004.en
- Connection compartment
- MDC_P004.fr
- Compartiment de raccordement
- MDC_P006.de
- Merkmale, die ein Anschlussgehäuse kennzeichnen
- MDC_P006.en
- properties characterizing a connection compartment
- MDC_P006.fr
- propriétés caractérisant un compartiment de raccordement
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA163,0112/2///61987#ABA156,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABA965,0112/2///61987#ABB393,0112/2///61987#ABA184,0112/2///61987#ABB502,0112/2///61987#ABA165,0112/2///61987#ABA180,0112/2///61987#ABA166,0112/2///61987#ABA394,0112/2///61987#ABB150,0112/2///61987#ABA397,0112/2///61987#ABA400,0112/2///61987#ABA589}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.