Connection head
properties characterizing a connection head of a flowmeter body without an integral transmitter
Hierarchy#
Ancestors (top) → ABC174 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties15#
classification of a housing according to its general protective purpose
classification of a housing according to its mechanical design
material of which a housing is made
degree of ingress protection offered by a housing or enclosure
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
horizontal distance between the left-hand and right-hand extremes of an object when standing in its normal position of use
vertical distance between the top and bottom of an object when standing in its normal position of use
horizontal distance between the front and back of an object when standing in its normal position of use or the distance from end to end of a long, thin object
internal diameter of a component measured at the point of maximum restriction
finishing specification of a device or flange surface expressed as roughness, either as a maximum depth or in a standardized roughness dimension
classification of a protective coating according to the type and finish of the coating material
type and finish of a material applied to provide a protective coating
tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment
standard to which a statement on an enclosure protection type or class refers
actual external diameter of a circular or cylindrical object
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC174
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Anschlusskopf
- MDC_P004.en
- Connection head
- MDC_P004.fr
- Tête de connexion
- MDC_P006.de
- Merkmale, die einen Anschlusskopf eines Durchflussmessinstruments ohne integrierten Messumformer kennzeichnen
- MDC_P006.en
- properties characterizing a connection head of a flowmeter body without an integral transmitter
- MDC_P006.fr
- propriétés caractérisant une tête de connexion d’un corps de débitmètre sans transmetteur intégré
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA156,0112/2///61987#ABA157,0112/2///61987#ABA640,0112/2///61987#ABA573,0112/2///61987#ABA574,0112/2///61987#ABB932,0112/2///61987#ABA910,0112/2///61987#ABA158,0112/2///61987#ABA916,0112/2///61987#ABA917,0112/2///61987#ABB010,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABB140}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.