Skip to content
OpenCDD
classITEM_CLASSv4rev 12022-12-09

Deployment design conditions [1]

0112/2///61987#ABC184

properties characterizing the deployment of the device in the pipe or vessel in order to obtain the specified performance

Hierarchy#

Ancestors (top) → ABC184 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties4#

ABA088special process conditionsENUM_STRING_TYPE

special process situation that results in further requirements or for which the device is prepared

precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions

ABA590mounting orientationENUM_STRING_TYPE

recommended orientation for installation of the device for which it is or should be designed

ABB969special preparation of non-wetted partsTRANSLATABLE_STRING_TYPE

precautions taken or to be taken during manufacture of the device regarding non-wetted parts to ensure its safe operation under special operation conditions

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
4
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00112
Dates
  • Original: 2017-12-07
  • Current version: 2022-12-09
  • Current revision: 2022-12-09

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (28 keys from source .xls) — click to expand
C002
C00112
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
1
C017.fr
0
C018.de
2021-08-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC184
MDC_P002_1
4
MDC_P002_2
1
MDC_P003_0
2022-12-09
MDC_P003_1
2017-12-07
MDC_P003_2
2022-12-09
MDC_P003_3
2022-12-09
MDC_P004.de
Errichtungsauslegungsbedingungen [1]
MDC_P004.en
Deployment design conditions [1]
MDC_P004.fr
Conditions de conception de déploiement [1]
MDC_P006.de
Merkmale, die die Errichtung des Geräts im Rohr oder Gefäß kennzeichnen, um die spezifizierte Leistung zu erzielen
MDC_P006.en
properties characterizing the deployment of the device in the pipe or vessel in order to obtain the specified performance
MDC_P006.fr
propriétés caractérisant le déploiement de l’appareil dans le tuyau ou réservoir afin d’obtenir les performances spécifiées de l’équipement de mesure (version de bloc 1)
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABA590,0112/2///61987#ABA088,0112/2///61987#ABA147,0112/2///61987#ABB969}
MDC_P019
false

Version history5#

  1. Current rev 01
    09 Dec 2022 · 09:47 UTC by BATCH 00000803
    View on cdd.iec.ch ↗
  2. superseded rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    01 Mar 2017 · 14:49 UTC by BATCH 00000732
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  5. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.