Electrical power input circuit
properties characterizing a permanent or temporary electrical power to be supplied to the device in order to maintain its function, which cannot be taken from the input signal
Hierarchy#
Ancestors (top) → ABC218 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties46#
current drawn by the device on start-up
provision of protection within a device against wiring mix-ups
@number of galvanic isolations
@number of explosion protection parameters for intrinsic safety
@number of cable specifications
operating voltage of the device as defined by the manufacturer and to which certain device properties are referenced
set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere
set of unwanted periodic deviations with respect to the average value of the supply voltage, occurring at frequencies which can be based on that of the line supply, related to the rated line voltage
classification of a power supply according to the current mode which can be used to operate a device
classification of a power supply according to the time behaviour of the voltage
highest frequency of a power supply with which the device can be operated
lowest frequency of a power supply with which the device can be operated
highest instantaneous power requirement of the device during normal operation
power that is typically taken from a power supply when the device is operating normally
operating frequency of the device as defined by the manufacturer and to which certain device properties are referenced
@number of electrical terminals
@number of batteries
number of wires used to supply power to the device
lowest universal voltage with which the device can be supplied in order that it operates within its specification
highest universal voltage at which a device or a device component can operate within its within its specification
lowest AC voltage with which the device can be supplied in order that it operates within its specification
highest AC voltage with which the device can be supplied in order that it operates within its specification
lowest DC voltage with which the device can be supplied in order that it operates within its specification
highest DC voltage with which the device can be supplied in order that it operates within its specification
greatest allowable periodic fluctuation of the supply voltage, expressed in absolute voltage values
highest current that may flow in a device circuit
behaviour of a device or measuring assembly upon a power failure
maximum allowable harmonic distortion of the AC power supply
provision of a current limitation circuit by a device or measuring assembly
maximum time that short-circuit may exist without causing any damage to the power source
ability of an electrical output or power supply to withstand short-circuit condition without any damage
reference to block ABC138
reference to block ABC148
reference to block ABC220
ABC863ref. Explosion protection device parameters for nonincendive installationCLASS_REFERENCE_TYPE(0112/2///61987#ABC233)reference to block ABC233
ABC867reference to Explosion protection parameters for intrinsic safety (passive)CLASS_REFERENCE_TYPE(0112/2///61987#ABC237)reference to block ABC237
reference to block ABC261
reference to block ABC522
lowest operating voltage of the device as defined by the manufacturer
highest operating voltage of the device as defined by the manufacturer
lowest operating frequency of the device as defined by the manufacturer
highest operating frequency of the device as defined by the manufacturer
classification of an electrical supply according to its usage
classification of an overvoltage protection according to its location
highest power loss in the device during normal operation
current used by the device as defined by the manufacturer and to which certain device properties are referenced
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 8
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00128- Dates
- Original: 2017-12-07
- Current version: 2023-01-23
- Current revision: 2023-01-23
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (28 keys from source .xls) — click to expand
- C002
- C00128
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 1
- C017.fr
- 0
- C018.de
- 2021-08-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC218
- MDC_P002_1
- 8
- MDC_P002_2
- 1
- MDC_P003_0
- 2023-01-23
- MDC_P003_1
- 2017-12-07
- MDC_P003_2
- 2023-01-23
- MDC_P003_3
- 2023-01-23
- MDC_P004.de
- Elektrische Eingangs-Energieversorgung
- MDC_P004.en
- Electrical power input circuit
- MDC_P004.fr
- Circuit d'entrée d'alimentation électrique
- MDC_P006.de
- Merkmale, die eine dauerhafte oder temporäre Energieversorgung für ein Gerät kennzeichnen, die zu deren Betrieb notwendig ist und nicht aus dem Eingangssignal bezogen werden kann
- MDC_P006.en
- properties characterizing a permanent or temporary electrical power to be supplied to the device in order to maintain its function, which cannot be taken from the input signal
- MDC_P006.fr
- propriétés caractérisant une alimentation électrique permanente ou temporaire à fournir à l’équipement de mesure afin de maintenir sa fonction, qui ne peut pas être extraite du signal d’entrée
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABE655,0112/2///61987#ABB604,0112/2///61987#ABA904,0112/2///61987#ABA588,0112/2///61987#ABD461,0112/2///61987#ABD462,0112/2///61987#ABA969,0112/2///61987#ABB063,0112/2///61987#ABD463,0112/2///61987#ABD464,0112/2///61987#ABB605,0112/2///61987#ABB606,0112/2///61987#ABB607,0112/2///61987#ABB608,0112/2///61987#ABB609,0112/2///61987#ABB610,0112/2///61987#ABB885,0112/2///61987#ABB886,0112/2///61987#ABA605,0112/2///61987#ABB611,0112/2///61987#ABA973,0112/2///61987#ABA972,0112/2///61987#ABA974,0112/2///61987#ABA975,0112/2///61987#ABP137,0112/2///61987#ABP163,0112/2///61987#ABB612,0112/2///61987#ABA063,0112/2///61987#ABB613,0112/2///61987#ABB614,0112/2///61987#ABA065,0112/2///61987#ABH387,0112/2///61987#ABB442,0112/2///61987#ABC768,0112/2///61987#ABD152,0112/2///61987#ABB617,0112/2///61987#ABA589,0112/2///61987#ABA387,0112/2///61987#ABC891,0112/2///61987#ABA390,0112/2///61987#ABC867,0112/2///61987#ABC863,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
- MDC_P019
- false
Version history9#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.