Explosion protection parameters for intrinsic safety
properties characterizing the explosion protection of an input or output circuit with passive behaviour or active behaviour
Hierarchy#
Ancestors (top) → ABC235 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties6#
classification of intrinsically safe apparatus and intrinsically safe parts of associated apparatus which are not capable of causing ignition under defined circumstances
@number of explosion protection permissible temperatures
plain text describing a specific set of explosion protection parameters
ABC868reference to Explosion protection permissible temperatureCLASS_REFERENCE_TYPE(0112/2///61987#ABC238)reference to block ABC238
ABD211reference to Safety related properties for active behaviourCLASS_REFERENCE_TYPE(0112/2///61987#ABC585)reference to block ABC585
ABD212reference to Safety related properties for passive behaviourCLASS_REFERENCE_TYPE(0112/2///61987#ABC586)reference to block ABC586
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC235
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Explosionsschutzparameter für Eigensicherheit
- MDC_P004.en
- Explosion protection parameters for intrinsic safety
- MDC_P004.fr
- Paramètres de protection contre les explosions pour sécurité intrinsèque
- MDC_P006.de
- Merkmale, die den Explosionsschutz eines Eingangs- oder Ausgangskreises mit passivem oder aktivem Verhalten kennzeichnen
- MDC_P006.en
- properties characterizing the explosion protection of an input or output circuit with passive behaviour or active behaviour
- MDC_P006.fr
- propriétés caractérisant la protection contre les explosions d’un circuit d’entrée ou de sortie avec comportement passif ou comportement actif
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB990,0112/2///61987#ABA391,0112/2///61987#ABB161,0112/2///61987#ABC868,0112/2///61987#ABD211,0112/2///61987#ABD212}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.