Explosion protection permissible temperature

0112/2///61987#ABC238

temperature class derating for explosion protection based on given operating and ambient temperatures

Hierarchy#

Ancestors (top) → ABC238 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties5#

ABA593temperature classENUM_STRING_TYPE

classification system of electrical apparatus, based on its maximum surface temperature, related to the specific explosive atmosphere for which it is intended to be used

ABA621minimum ambient temperatureREAL_MEASURE_TYPE

lowest ambient temperature for which a device is or should be designed to operate within its specified limits

ABA623maximum ambient temperatureREAL_MEASURE_TYPE

highest ambient temperature for which a device is or should be designed to operate within its specified limits

ABA918minimum process temperatureREAL_MEASURE_TYPE

lowest process temperature for which a device is or should be designed to operate within its specified limits

ABA919maximum process temperatureREAL_MEASURE_TYPE

highest process temperature for which a device is or should be designed to operate within its specified limits

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
5
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00004
Dates
  • Original: 2013-08-27
  • Current version: 2018-03-20
  • Current revision: 2018-03-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (25 keys from source .xls) — click to expand
C002
C00004
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC238
MDC_P002_1
5
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2013-08-27
MDC_P003_2
2018-03-20
MDC_P003_3
2018-03-20
MDC_P004.de
Zulässige Temperatur für Explosionsschutz
MDC_P004.en
Explosion protection permissible temperature
MDC_P004.fr
Température tolérée de protection contre les explosions
MDC_P006.de
Derating der Temperaturklasse für Explosionsschutz basierend auf vorgegebenen Betriebs- und Umgebungstemperaturen
MDC_P006.en
temperature class derating for explosion protection based on given operating and ambient temperatures
MDC_P006.fr
déclassement de classe de température pour la protection contre les explosions basé sur des températures de fonctionnement et ambiante données
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABA593,0112/2///61987#ABA621,0112/2///61987#ABA623,0112/2///61987#ABA918,0112/2///61987#ABA919}

Version history6#

  1. Current rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    View on cdd.iec.ch ↗
  2. superseded rev 01
    20 Mar 2018 · 12:22 UTC by BATCH 00000755
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    01 Mar 2017 · 14:50 UTC by BATCH 00000732
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    22 Mar 2016 · 10:24 UTC by BATCH 00000714
    ↓ Version JSON
    View on cdd.iec.ch ↗
  5. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  6. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.