Flowtube assembly
properties characterizing a flow tube assembly
Hierarchy#
Ancestors (top) → ABC246 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties28#
construction standard used for the engineering and fabrication of a component or connection
roughness of the surface of a measuring tube
precautions taken or to be taken during manufacture of the device regarding wetted parts to ensure its safe operation under special operation conditions
alphanumeric designation of size for components of a pipe work system, which is used for reference purposes
finishing specification of a surface expressed as roughness, either as a maximum depth or in a standardized roughness dimension, for parts additional to the main part
classification of a component surface finish according to the method used to achieve it
internal diameter of a component measured at the point of maximum restriction
material of a protective coating or lining that prevents the contact of a fluid with the material from which the equipment is made
for a Coriolis flowmeter, provision made to drain out process material from the device with no assistance under suitable pressure conditions
classification of a measuring tube according to its mechanical design
tightness of a pressure or vacuum housing expressed in terms of the leakage rate to or from its environment
characteristic of a pipe rating system giving the wall thickness for the pipe nominal diameter
wall thickness of a measuring tube
set of parts used for the mounting or installation of a device
classification of a provision to smooth turbulences of a fluid stream
classification of a seal according to its construction
thickness of a lining or cladding used to prevent the contact of process fluid with the material from which the equipment is made
degree of roughness of the surface of a lining or coating expressed as a length
@number of additional wetted parts materials
degree of reduction of line size related to the process connection diameter
@number of material of additional parts
@number of material of wetted inner seals
classification of a feedthrough according to the mechanical design
reference to block ABC338
reference to block ABC339
reference to block ABC364
reference to block ABC374
reference to block ABC403
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC246
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Aufbau des Messrohrs
- MDC_P004.en
- Flowtube assembly
- MDC_P004.fr
- Ensemble de tube d’écoulement
- MDC_P006.de
- Merkmale, die einen Aufbau eines Messrohrs kennzeichnen
- MDC_P006.en
- properties characterizing a flow tube assembly
- MDC_P006.fr
- propriétés caractérisant un ensemble de tuyère
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB068,0112/2///61987#ABA145,0112/2///61987#ABA639,0112/2///61987#ABA576,0112/2///61987#ABB459,0112/2///61987#ABB340,0112/2///61987#ABB382,0112/2///61987#ABA146,0112/2///61987#ABA633,0112/2///61987#ABD004,0112/2///61987#ABA911,0112/2///61987#ABB453,0112/2///61987#ABB456,0112/2///61987#ABB396,0112/2///61987#ABB915,0112/2///61987#ABD033,0112/2///61987#ABB457,0112/2///61987#ABC969,0112/2///61987#ABA602,0112/2///61987#ABA147,0112/2///61987#ABB140,0112/2///61987#ABB051,0112/2///61987#ABC028,0112/2///61987#ABB383,0112/2///61987#ABB387,0112/2///61987#ABC994,0112/2///61987#ABB887,0112/2///61987#ABC968}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.