Skip to content
OpenCDD
classITEM_CLASSv3rev 12023-01-23

Galvanic isolation

0112/2///61987#ABC261

properties characterizing the galvanic isolation of the device circuits

Hierarchy#

ABA000 Equipment for industr… ABV001 Libraries ABV501 Block ABC261 Galvanic isolation ABC261 Galvanic isolation

Ancestors (top) → ABC261 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties9#

9 / 9
ABA969type of voltageENUM_STRING_TYPE

classification of a power supply according to the time behaviour of the voltage

ABB914duration of testREAL_MEASURE_TYPE

length of time for which a given test procedure is applied

ABP181withstand voltageREAL_MEASURE_TYPE

value of the test voltage to be applied under specified conditions in a withstand test, during which a specified number of disruptive discharges is tolerated

ABP189first test pointENUM_STRING_TYPE

first of two test points between which a galvanic isolation is stated

ABP194second test pointENUM_STRING_TYPE

second of two test points between which a galvanic isolation is stated

ABP201test criteriumTRANSLATABLE_STRING_TYPE

criterium to be met to fulfil a test specification

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
3
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00128
Dates
  • Original: 2017-12-07
  • Current version: 2023-01-23
  • Current revision: 2023-01-23

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (28 keys from source .xls) — click to expand
C002
C00128
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC261
MDC_P002_1
3
MDC_P002_2
1
MDC_P003_0
2023-01-23
MDC_P003_1
2017-12-07
MDC_P003_2
2023-01-23
MDC_P003_3
2023-01-23
MDC_P004.de
Galvanische Trennung
MDC_P004.en
Galvanic isolation
MDC_P004.fr
Isolation galvanique
MDC_P006.de
Merkmale, die die galvanische Trennung von Gerätekreisen kennzeichnen
MDC_P006.en
properties characterizing the galvanic isolation of the device circuits
MDC_P006.fr
propriétés caractérisant l’isolation galvanique des circuits de l’appareil
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABP189,0112/2///61987#ABP194,0112/2///61987#ABA969,0112/2///61987#ABP181,0112/2///61987#ABP201,0112/2///61987#ABP129,0112/2///61987#ABB914,0112/2///61987#ABP192,0112/2///61987#ABA389}
MDC_P019
false

Version history5#

  1. Current rev 01
    23 Jan 2023 · 14:53 UTC by BATCH 00000807
    View on cdd.iec.ch ↗
  2. superseded rev 02
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    20 Mar 2018 · 12:22 UTC by BATCH 00000755
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    23 Mar 2016 · 15:00 UTC by BATCH 00000715
    ↓ Version JSON
    View on cdd.iec.ch ↗
  5. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.