Impulse line
properties characterizing the piping used to connect pressure signals to a pressure transmitter
Hierarchy#
Ancestors (top) → ABC270 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties17#
construction standard used for the engineering and fabrication of a component or connection
difference between the outside and the inside diameter of a pipe, conduit or vessel, divided by two
alphanumeric designation of size for components of a pipe work system, which is used for reference purposes
alphanumeric designation of a pressure allowable within a piping system or piece of equipment, which is used for reference purposes
internal diameter of a component measured at the point of maximum restriction
thickness of thermal insulation and mechanical protection added to the outside of a piece of equipment
way in which thermal insulation is applied to a component
cardinality property for process connection
characteristic of a pipe rating system giving the wall thickness for the pipe nominal diameter
standard on which a pipe schedule is based
user specific alphanumeric character sequence identifying a specification of piping components for use within its confines and which contains the definition of pipe and all related components that are to be used under a specific pressure, temperature condition – usually including material and further information
material of the insulation of a component
length of tube or pipe including end connections
classification of a vessel to separate gas and its condensates according to its method of fabrication
reference to block ABU458
reference to block ABC353
reference to block ABC042
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC270
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Wirkdruckleitung
- MDC_P004.en
- Impulse line
- MDC_P004.fr
- Ligne d'impulsion
- MDC_P006.de
- Merkmale, die die Leitung kennzeichnen, mit der Drucksignale an einen Druckmessumformer übertragen werden
- MDC_P006.en
- properties characterizing the piping used to connect pressure signals to a pressure transmitter
- MDC_P006.fr
- propriétés caractérisant la canalisation utilisée pour connecter les signaux de pression à un transmetteur de pression
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA576,0112/2///61987#ABA591,0112/2///61987#ABB340,0112/2///61987#ABB341,0112/2///61987#ABB918,0112/2///61987#ABA910,0112/2///61987#ABA554,0112/2///61987#ABB343,0112/2///61987#ABA145,0112/2///61987#ABC983,0112/2///61987#ABA958,0112/2///61987#ABB347,0112/2///61987#ABA959,0112/2///61987#ABB919,0112/2///61987#ABB102,0112/2///61987#ABC855,0112/2///61987#ABD284}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.