Insertion ultrasonic flowmeter
properties characterizing an insertion-type ultrasonic flowmeter
Hierarchy#
Ancestors (top) → ABC302 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties14#
degree of ingress protection offered by a housing or enclosure
extent of protection provided by an enclosure against access to hazardous parts, against ingress of solid foreign objects and/or ingress of water and verified by standardized test methods
length of a cable connecting two devices
classification of a sensor assembly of an ultrasonic flowmeter according to the number of beams in use
standard to which a statement on an enclosure protection type or class refers
classification of a sensor assembly of an ultrasonic flowmeter according to its mounting arrangement
classification of a sensor assembly of an ultrasonic flowmeter according to the number of beam traverses in use
number of sensor (transmitter/receiver) heads supplied with the sensor assembly
vertical distance between the top and bottom of the device when standing in its normal position of use
distance between two diametrically opposed outer walls of a sensor holder
angle of the ultrasonic beam when a sensor head is mounted in a sensor holder
reference to block ABC391
reference to block ABC392
ABD030reference to Material of ultrasonic flow sensor headCLASS_REFERENCE_TYPE(0112/2///61987#ABC400)reference to block ABC400
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Remark
- 17 ABC302.17
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (26 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC302
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Sonden-Ultraschalldurchflussmesser
- MDC_P004.en
- Insertion ultrasonic flowmeter
- MDC_P004.fr
- Débitmètre à ultrasons à insertion
- MDC_P006.de
- Merkmale, die einen Sonden-Ultraschalldurchflussmesser kennzeichnen
- MDC_P006.en
- properties characterizing an insertion-type ultrasonic flowmeter
- MDC_P006.fr
- propriétés caractérisant un débitmètre à ultrasons de type à insertion
- MDC_P009.en
- 17 ABC302.17
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB488,0112/2///61987#ABB486,0112/2///61987#ABB130,0112/2///61987#ABB487,0112/2///61987#ABB489,0112/2///61987#ABB490,0112/2///61987#ABB491,0112/2///61987#ABB007,0112/2///61987#ABA558,0112/2///61987#ABA179,0112/2///61987#ABB386,0112/2///61987#ABD030,0112/2///61987#ABD022,0112/2///61987#ABD021}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.