Limiting environmental design conditions
properties characterizing the extreme range of environmental conditions that a device shall be designed to withstand without permanent damage
Hierarchy#
Ancestors (top) → ABC316 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties15#
highest rate of change of ambient temperature a device can or should withstand without permanent impairment of operating characteristics
lowest air pressure to which a device may be subject between the time of construction and the time of operation without permanent impairment of operating characteristics
lowest relative humidity to which a device may be subject between the time of construction and the time of operation without permanent impairment of operating characteristics
highest relative humidity to which a device may be subject between the time of construction and the time of operation without permanent impairment of operating characteristics
standard to which a statement on vibration resistance refers
standard to which a statement on mechanical shock resistance refers
range of sinusoidal vibrations of a given severity the equipment is or shall be designed to withstand without permanent impairment of operating characteristics
highest ambient temperature a device can or should withstand without permanent impairment of operating characteristics
lowest ambient temperature a device can or should withstand without permanent impairment of operating characteristics
lowest temperature to which a device may be subject between the time of construction and the time of operation without permanent impairment of operating characteristics
highest temperature to which a device may be subject between the time of construction and the time of operation without permanent impairment of operating characteristics
degree of sudden mechanical loading a device can or should be designed to withstand without permanent impairment of operating characteristics
highest pressure to which a device may be subject between the time of construction and the time of operation
@number of vibration test conditions
reference to block ABD397
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Note
- The device must measure within specification, if necessary after calibration, when the condition returns to its normal range
- Version
- 8
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- IEC/SC 65E
- Change request
C00112- Dates
- Original: 2018-03-21
- Current version: 2022-12-09
- Current revision: 2022-12-09
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (30 keys from source .xls) — click to expand
- C002
- C00112
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 1
- C017.fr
- 0
- C018.de
- 2021-08-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC316
- MDC_P002_1
- 8
- MDC_P002_2
- 1
- MDC_P003_0
- 2022-12-09
- MDC_P003_1
- 2018-03-21
- MDC_P003_2
- 2022-12-09
- MDC_P003_3
- 2022-12-09
- MDC_P004.de
- Umgebungsauslegungsbedingungen (Grenzbedingungen)
- MDC_P004.en
- Limiting environmental design conditions
- MDC_P004.fr
- Conditions de conception environnementales limitantes
- MDC_P006.de
- Merkmale, die die extremen Umgebungsbedingungen charakterisieren, für die ein Gerät auszulegen ist, ohne dass ein bleibender Schaden entsteht
- MDC_P006.en
- properties characterizing the extreme range of environmental conditions that a device shall be designed to withstand without permanent damage
- MDC_P006.fr
- propriétés caractérisant l’étendue extrême de conditions environnementales qu’un appareil doit pouvoir supporter par conception sans dommages permanents de ses caractéristiques de mesure
- MDC_P008.de
- Das Gerät muss im Rahmen seiner Spezifizierung messen, gegebenenfalls nach einer Kalibrierung, wenn die Bedingungen wieder im Normalbereich sind
- MDC_P008.en
- The device must measure within specification, if necessary after calibration, when the condition returns to its normal range
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- IEC/SC 65E
- MDC_P014
- {0112/2///61987#ABA923,0112/2///61987#ABA922,0112/2///61987#ABA101,0112/2///61987#ABA924,0112/2///61987#ABA925,0112/2///61987#ABA103,0112/2///61987#ABB325,0112/2///61987#ABA106,0112/2///61987#ABA107,0112/2///61987#ABD396,0112/2///61987#ABD398,0112/2///61987#ABA572,0112/2///61987#ABA108,0112/2///61987#ABA963,0112/2///61987#ABA109}
- MDC_P019
- false
Version history9#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.