Pressure measurement instrument installation
properties characterizing special measurement installation requirements for pressure and differential pressure measurements
Hierarchy#
Ancestors (top) → ABC411 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties11#
text describing the designated use of the device
for an elevated or suppressed-zero range, amount by which the measured variable is above (zero point elevation) or below (zero point suppression) the lower range value
classification of a pressure transmitter or the pressure gauge according to its mounting position
vertical distance between two process connections
distance between two process connections irrespective of their mounting orientation
vertical distance between the high/single pressure process connection and the sensing element of the pressure transmitter or pressure gauge
vertical distance between the low pressure process connection and the sensing element of the pressure transmitter or pressure gauge
distance between a liquid level at upper range limit and the lower process connection of the pressure transmitter or pressure gauge
distance between a liquid level at lower range limit and the lower process connection of a pressure transmitter or pressure gauge
distance, projected to the vertical axis, between the vessel zero reference point and the instrument mounting reference
calculated height of a liquid resulting from the measured differential pressure and the total effective fluid density
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Note
- Level measurements requirements are included
- Version
- 2
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-09-27
- Current version: 2016-05-24
- Current revision: 2016-05-24
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (28 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-11-24
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABC411
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-27
- MDC_P003_2
- 2016-05-24
- MDC_P003_3
- 2016-05-24
- MDC_P004.de
- Installation des Druckmessgeräts
- MDC_P004.en
- Pressure measurement instrument installation
- MDC_P004.fr
- Installation d'instrument de mesure de pression
- MDC_P006.de
- Merkmale, die spezielle Anforderungen an die Installation von Messgeräten für Druck- und Differenzdruckmessungen kennzeichnen
- MDC_P006.en
- properties characterizing special measurement installation requirements for pressure and differential pressure measurements
- MDC_P006.fr
- propriétés caractérisant les exigences spéciales relatives à l'installation de mesure pour les mesures de pression et de pression différentielle
- MDC_P008.de
- Anforderungen an Füllstandmessung sind inbegriffen
- MDC_P008.en
- Level measurements requirements are included
- MDC_P008.fr
- Les exigences relatives aux mesures de niveau y sont incluses
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB014,0112/2///61987#ABB999,0112/2///61987#ABC000,0112/2///61987#ABC001,0112/2///61987#ABC002,0112/2///61987#ABC003,0112/2///61987#ABC004,0112/2///61987#ABC005,0112/2///61987#ABC006,0112/2///61987#ABC007,0112/2///61987#ABB996}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.