Performance of remote seal
properties characterizing the performance of the remote seal with regard to measurement accuracy and dynamic behaviour
Hierarchy#
Ancestors (top) → ABC502 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties9#
change in output of a remote seal caused by a change in ambient temperature with respect to reference conditions, expressed as the average of the upscale and downscale errors at selected test temperatures
change in output of a remote seal caused by a change in process temperature with respect to reference conditions, expressed as the average of the upscale and downscale errors at selected test temperatures
minimum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value
maximum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value
greatest change in the output of a remote seal caused by varying the temperature over the rated temperature range
minimum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value
time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value, which is used for reference purposes
time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value, which is used for reference purposes
maximum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-09-27
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-09-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABC502
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-27
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Leistungsdaten des Druckmittlers
- MDC_P004.en
- Performance of remote seal
- MDC_P004.fr
- Performances de séparateur
- MDC_P006.de
- Merkmale, die die Leistung des Druckmittlers in Bezug auf Messgenauigkeit und dynamisches Verhalten kennzeichnen
- MDC_P006.en
- properties characterizing the performance of the remote seal with regard to measurement accuracy and dynamic behaviour
- MDC_P006.fr
- propriétés caractérisant les performances du séparateur pour ce qui concerne la précision de mesure et le comportement dynamique
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB036,0112/2///61987#ABB037,0112/2///61987#ABB964,0112/2///61987#ABB038,0112/2///61987#ABB965,0112/2///61987#ABB966,0112/2///61987#ABB967,0112/2///61987#ABB039,0112/2///61987#ABB968}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.