Skip to content
OpenCDD
classITEM_CLASSv3rev 12018-03-20

Performance of remote seal

0112/2///61987#ABC502

properties characterizing the performance of the remote seal with regard to measurement accuracy and dynamic behaviour

Hierarchy#

Ancestors (top) → ABC502 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties9#

9 / 9

change in output of a remote seal caused by a change in ambient temperature with respect to reference conditions, expressed as the average of the upscale and downscale errors at selected test temperatures

change in output of a remote seal caused by a change in process temperature with respect to reference conditions, expressed as the average of the upscale and downscale errors at selected test temperatures

ABB038minimum step response time T90REAL_MEASURE_TYPE

minimum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value

ABB039maximum step response time T90REAL_MEASURE_TYPE

maximum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value

ABB965minimum step response time T63REAL_MEASURE_TYPE

minimum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value

ABB966nominal step response time T90REAL_MEASURE_TYPE

time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 90% of its final steady state value, which is used for reference purposes

ABB967nominal step response time T63REAL_MEASURE_TYPE

time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value, which is used for reference purposes

ABB968maximum step response time T63REAL_MEASURE_TYPE

maximum time duration from a step change in the input signal to a system for the change in output of the system to reach for the first time 63% of its final steady state value

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
3
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00004
Dates
  • Original: 2013-09-27
  • Current version: 2018-03-20
  • Current revision: 2018-03-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (25 keys from source .xls) — click to expand
C002
C00004
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-09-27
C019.de
Mr. W. Hartmann
C019.fr
UTE
MDC_P001_5
0112/2///61987#ABC502
MDC_P002_1
3
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2013-09-27
MDC_P003_2
2018-03-20
MDC_P003_3
2018-03-20
MDC_P004.de
Leistungsdaten des Druckmittlers
MDC_P004.en
Performance of remote seal
MDC_P004.fr
Performances de séparateur
MDC_P006.de
Merkmale, die die Leistung des Druckmittlers in Bezug auf Messgenauigkeit und dynamisches Verhalten kennzeichnen
MDC_P006.en
properties characterizing the performance of the remote seal with regard to measurement accuracy and dynamic behaviour
MDC_P006.fr
propriétés caractérisant les performances du séparateur pour ce qui concerne la précision de mesure et le comportement dynamique
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABB036,0112/2///61987#ABB037,0112/2///61987#ABB964,0112/2///61987#ABB038,0112/2///61987#ABB965,0112/2///61987#ABB966,0112/2///61987#ABB967,0112/2///61987#ABB039,0112/2///61987#ABB968}

Version history4#

  1. Current rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    View on cdd.iec.ch ↗
  2. superseded rev 01
    01 Mar 2017 · 14:50 UTC by BATCH 00000732
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.