Pneumatic/hydraulic supply [2]

0112/2///61987#ABC520

properties characterizing a pneumatic or hydraulic power supply available for or required by a device

Hierarchy#

Ancestors (top) → ABC520 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties18#

18 / 18
ABA330base gauge pressureREAL_MEASURE_TYPE

gauge pressure used to calculate variables to reference conditions

ABA625dew pointREAL_MEASURE_TYPE

temperature at which one or more vapour components condense to liquid phase at a given operating pressure

ABB359rated gauge pressureREAL_MEASURE_TYPE

gauge pressure normally required for a particular application

ABB360minimum gauge pressure of supplyREAL_MEASURE_TYPE

lowest gauge pressure provided by a hydraulic or pneumatic power supply or to be applied to a pneumatic or hydraulic device

ABB361maximum gauge pressure of supplyREAL_MEASURE_TYPE

highest gauge pressure provided by a hydraulic or pneumatic power supply or to be applied to a pneumatic or hydraulic device

ABB634steady state fluid consumptionREAL_MEASURE_TYPE

fluid consumption in no load condition, expressed as normalized volume flow at a given supply pressure

ABB781base temperatureREAL_MEASURE_TYPE

temperature used to calculate variables to reference conditions

ABB930quality of fluidTRANSLATABLE_STRING_TYPE

classification or requirement of pneumatic or hydraulic fluid according to its purity and moisture content

ABB941maximum fluid consumptionREAL_MEASURE_TYPE

highest flow of fluid drawn by the pneumatic/hydraulic power supply, expressed as normalized volume flow at a given supply pressure

ABD525type of fluidTRANSLATABLE_STRING_TYPE

classification of a fluid according to its chemical composition or name

ABE652typical fluid consumptionREAL_MEASURE_TYPE

fluid consumption under typical operating conditions of the device, expressed as actual volume flow

fluid consumption under typical operating conditions of the device, expressed as normalized volume flow at a given base pressure and base temperature

ABH262minimum temperature of fluidREAL_MEASURE_TYPE

lowest temperature that a pneumatic or hydraulic fluid of a pneumatic or hydraulic supply may have

ABH263maximum temperature of fluidREAL_MEASURE_TYPE

highest temperature that a pneumatic or hydraulic fluid of a pneumatic or hydraulic supply may have

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
8
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
IEC/SC 65E
Change request
C00128
Dates
  • Original: 2017-12-07
  • Current version: 2023-01-23
  • Current revision: 2023-01-23

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (28 keys from source .xls) — click to expand
C002
C00128
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
1
C017.fr
0
C018.de
2021-08-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC520
MDC_P002_1
8
MDC_P002_2
1
MDC_P003_0
2023-01-23
MDC_P003_1
2017-12-07
MDC_P003_2
2023-01-23
MDC_P003_3
2023-01-23
MDC_P004.de
Pneumatische/hydraulische Energieversorgung [2]
MDC_P004.en
Pneumatic/hydraulic supply [2]
MDC_P004.fr
Alimentation pneumatique/hydraulique [2]
MDC_P006.de
Merkmale, die eine verfügbare oder vom Gerät benötigte, pneumatische oder hydraulische Energieversorgung kennzeichnen
MDC_P006.en
properties characterizing a pneumatic or hydraulic power supply available for or required by a device
MDC_P006.fr
propriétés caractérisant une alimentation pneumatique ou hydraulique disponible au point de mesurage ou exigées par l’appareil (version de bloc 2)
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
IEC/SC 65E
MDC_P014
{0112/2///61987#ABE654,0112/2///61987#ABD525,0112/2///61987#ABB359,0112/2///61987#ABB360,0112/2///61987#ABB361,0112/2///61987#ABB634,0112/2///61987#ABB941,0112/2///61987#ABE652,0112/2///61987#ABE653,0112/2///61987#ABA330,0112/2///61987#ABB781,0112/2///61987#ABH262,0112/2///61987#ABH263,0112/2///61987#ABA342,0112/2///61987#ABD538,0112/2///61987#ABA625,0112/2///61987#ABB930,0112/2///61987#ABD526}
MDC_P019
false

Version history9#

  1. Current rev 01
    23 Jan 2023 · 14:53 UTC by BATCH 00000807
    View on cdd.iec.ch ↗
  2. superseded rev 01
    09 Dec 2022 · 09:47 UTC by BATCH 00000803
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    ↓ Version JSON
    View on cdd.iec.ch ↗
  4. superseded rev 01
    20 Mar 2018 · 12:22 UTC by BATCH 00000755
    ↓ Version JSON
    View on cdd.iec.ch ↗
  5. superseded rev 01
    01 Mar 2017 · 14:50 UTC by BATCH 00000732
    ↓ Version JSON
    View on cdd.iec.ch ↗
  6. superseded rev 01
    02 May 2016 · 12:35 UTC by BATCH 00000716
    ↓ Version JSON
    View on cdd.iec.ch ↗
  7. superseded rev 01
    22 Mar 2016 · 10:24 UTC by BATCH 00000714
    ↓ Version JSON
    View on cdd.iec.ch ↗
  8. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  9. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.