Pressure-temperature design ratings
properties characterizing process safety conditions
Hierarchy#
Ancestors (top) → ABC533 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties12#
maximum gauge pressure that does not cause any rupture of the device
minimum temperature at which membrane stress may occur
@number of design deratings
maximum permitted test pressure that can be or is applied without changing the device specification
maximum gauge pressure applied to a device at which the device is not damaged but the process fluid leaks
reference to block ABC188
minimum absolute pressure for which the equipment is designed, as specified by the manufacturer
minimum gauge pressure for which the equipment is designed, as specified by the manufacturer
highest absolute pressure for which the equipment is designed, as specified by the manufacturer
highest gauge pressure for which the equipment is designed, as specified by the manufacturer
minimum temperature for which the equipment is designed, as specified by the manufacturer
highest temperature for which the equipment is designed, as specified by the manufacturer
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 4
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC533
- MDC_P002_1
- 4
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Druck-Temperaturauslegung
- MDC_P004.en
- Pressure-temperature design ratings
- MDC_P004.fr
- Caractéristiques de conception de pression-température affectées
- MDC_P006.de
- Merkmale, die Bedingungen für die Prozesssicherheit kennzeichnen
- MDC_P006.en
- properties characterizing process safety conditions
- MDC_P006.fr
- propriétés caractérisant les conditions de sécurité de processus
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD331,0112/2///61987#ABD332,0112/2///61987#ABD333,0112/2///61987#ABD334,0112/2///61987#ABD335,0112/2///61987#ABD336,0112/2///61987#ABB893,0112/2///61987#ABA133,0112/2///61987#ABB944,0112/2///61987#ABA135,0112/2///61987#ABA136,0112/2///61987#ABC818}
Version history5#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.