RTD input
properties characterizing an auxiliary RTD input
Hierarchy#
Ancestors (top) → ABC579 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties17#
@number of galvanic isolations
@number of cable specifications
standard to which an RTD sensor type refers
lower range end-value that has been configured at the factory
upper range end-value that has been configured at the factory
classification of RTDs based on material and resistance used
current drawn by a RTD sensing element during normal operation
greatest resistance that can be exhibited by the sensor connecting cable, if the device is to operate within the specified accuracy limits
classification of a RTD or resistor connection based on the number of wires used
@number of electrical terminals
lowest RTD input signal that the device can be adjusted to measure within the specified accuracy limits
highest RTD input signal that the device can be adjusted to measure within the specified accuracy limits
classification of a resistance temperature detector according to a type code in a standard
frequency characteristics of a line filter used to block interference
reference to block ABC148
reference to block ABC220
reference to block ABC261
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-09-27
- Current version: 2013-09-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-09-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABC579
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-27
- MDC_P003_2
- 2013-09-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- WTH-Eingang
- MDC_P004.en
- RTD input
- MDC_P004.fr
- Entrée de sonde de température à résistance (SR)
- MDC_P006.de
- Merkmale, die einen WTH-Hilfseingang kennzeichnen
- MDC_P006.en
- properties characterizing an auxiliary RTD input
- MDC_P006.fr
- propriétés caractérisant une entrée de SR auxiliaire
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB088,0112/2///61987#ABB203,0112/2///61987#ABA409,0112/2///61987#ABB091,0112/2///61987#ABB171,0112/2///61987#ABB172,0112/2///61987#ABA930,0112/2///61987#ABA931,0112/2///61987#ABB089,0112/2///61987#ABB090,0112/2///61987#ABB260,0112/2///61987#ABA387,0112/2///61987#ABC891,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.