Skip to content
OpenCDD
classITEM_CLASSv1rev 22013-08-27

Retractable thermal mass flow transmitter

0112/2///61987#ABC583

properties characterizing a retractable thermal mass flowmeter

Hierarchy#

Ancestors (top) → ABC583 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties24#

24 / 24
ABB106minimum nominal diameter of pipelineTRANSLATABLE_STRING_TYPE

minimum nominal diameter of the pipeline that can be used for operation of the device within the specified accuracy limits

ABB469length of insertion probeREAL_MEASURE_TYPE

distance from the end of the probe to the bottom of the connection head compartment

ABB471length of protective tubeREAL_MEASURE_TYPE

distance from the end of the protective tube to the bottom of the process connection

ABB480type of hot tapENUM_STRING_TYPE

classification of a hot tap according to the maximum extraction pressure for which it is designed

ABB548style of positioningTRANSLATABLE_STRING_TYPE

classification of the means of positioning a retractable insertion probe according to its mechanical design

ABB549style of safety mechanismENUM_STRING_TYPE

classification of the safety mechanism of a retractable insertion probe according to its mechanical design

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Remark
16 ABC583.16
Version
1
Revision
2
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00004
Dates
  • Original: 2013-08-27
  • Current version: 2013-08-27
  • Current revision: 2014-06-18

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (26 keys from source .xls) — click to expand
C002
C00004
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-08-27
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC583
MDC_P002_1
1
MDC_P002_2
2
MDC_P003_0
2018-03-28
MDC_P003_1
2013-08-27
MDC_P003_2
2013-08-27
MDC_P003_3
2014-06-18
MDC_P004.de
Rückziehbarer thermischer Massedurchflussmessumformer
MDC_P004.en
Retractable thermal mass flow transmitter
MDC_P004.fr
Transmetteur thermique de débit massique rétractable
MDC_P006.de
Merkmale, die einen rückziehbaren thermischen Massedurchflussmessumformer kennzeichnen
MDC_P006.en
properties characterizing a retractable thermal mass flowmeter
MDC_P006.fr
propriétés caractérisant un débitmètre thermique massique rétractable
MDC_P009.en
16 ABC583.16
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABB480,0112/2///61987#ABB469,0112/2///61987#ABB470,0112/2///61987#ABB471,0112/2///61987#ABB472,0112/2///61987#ABD013,0112/2///61987#ABD014,0112/2///61987#ABD001,0112/2///61987#ABD015,0112/2///61987#ABB106,0112/2///61987#ABB105,0112/2///61987#ABB547,0112/2///61987#ABB479,0112/2///61987#ABB481,0112/2///61987#ABB482,0112/2///61987#ABB548,0112/2///61987#ABB549,0112/2///61987#ABC998,0112/2///61987#ABD000,0112/2///61987#ABC970,0112/2///61987#ABC999,0112/2///61987#ABB483,0112/2///61987#ABB484,0112/2///61987#ABB485}

Version history2#

  1. Current rev 02
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    View on cdd.iec.ch ↗
  2. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.