classITEM_CLASSv2rev 12016-05-24

Structural design of a variable area flow transmitter or gauge

0112/2///61987#ABC638

properties characterizing the constructional details of a flow transmitter or flow gauge that throttles a stream through a constriction, the area of which changes to keep a constant differential pressure, in order to measure flow rate

Hierarchy#

Ancestors (top) → ABC638 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties22#

22 / 22
ABA202interval of scaleREAL_TYPE

difference between two markings expressed in the units of measure of the scale

ABA590mounting orientationENUM_STRING_TYPE

recommended orientation for installation of the device for which it is or should be designed

ABA901accuracy classTRANSLATABLE_STRING_TYPE

category of instruments or components thereof, all of which are intended to comply with a set of specifications regarding uncertainty

ABA935magnetic filterTRANSLATABLE_STRING_TYPE

type or existence of a magnetic filter

ABB114type of adjusting valveENUM_STRING_TYPE

classification of the flow adjusting valve of a variable area flow transmitter according to its mechanical construction

ABB115style of flow controlENUM_STRING_TYPE

classification of the means to control the flow through a variable area flowmeter according to the method used

ABB117type of trip switchTRANSLATABLE_STRING_TYPE

classification of a trip switch according to its electrical and mechanical construction

ABB118type of signal tappingENUM_STRING_TYPE

classification of the tapping of a trip switch according to the method used to sense a change in status

ABB119style of float elementENUM_STRING_TYPE

classification of the float element of a variable area flow transmitter according to its shape

ABB120material of liningTRANSLATABLE_STRING_TYPE

material of a protective lining that prevents the contact of a fluid with the material from which the equipment is made

ABB121length of scaleREAL_MEASURE_TYPE

length of a straight indicating scale of a measuring device

ABB122style of scaleENUM_STRING_TYPE

classification of the scale of a mechanical indicator according to the shape

ABB123type of indicator extensionENUM_STRING_TYPE

classification of the provision made for positioning an indicator from a source of heat according to the degree of extension

ABB992type of indicatorENUM_STRING_TYPE

classification of an indicator according to its method of providing readings

ABB994unit of scaleSTRING_TYPE

short name of the standardized engineering unit indicated by a scale

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
2
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00004
Dates
  • Original: 2013-08-27
  • Current version: 2016-05-24
  • Current revision: 2016-05-24

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (25 keys from source .xls) — click to expand
C002
C00004
C016
Standard
C017.de
0
C017.fr
0
C018.de
2014-12-12
C018.fr
2013-11-24
C019.de
Mr. W. Hartmann
C019.fr
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABC638
MDC_P002_1
2
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2013-08-27
MDC_P003_2
2016-05-24
MDC_P003_3
2016-05-24
MDC_P004.de
Konstruktiver Aufbau eines Schwebekörper-Durchflussmessers
MDC_P004.en
Structural design of a variable area flow transmitter or gauge
MDC_P004.fr
Conception structurelle d’un transmetteur ou jauge de débit à section variable
MDC_P006.de
Merkmale, die die konstruktiven Details eines Differenzdruck-Durchflussmessmessgeräts oder -Anzeigers kennzeichnen, bei dem zur Messung des Durchsatzes ein Mediumsstrom an einer Verengung gedrosselt wird, deren Fläche variabel ist, um den Differenzdruck konstant zu halten
MDC_P006.en
properties characterizing the constructional details of a flow transmitter or flow gauge that throttles a stream through a constriction, the area of which changes to keep a constant differential pressure, in order to measure flow rate
MDC_P006.fr
propriétés caractérisant les détails de construction d’un transmetteur ou jauge de débit qui restreint un flux à travers un étranglement, dont la section change pour maintenir une pression différentielle constante, afin de mesurer le débit
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABB113,0112/2///61987#ABB993,0112/2///61987#ABB119,0112/2///61987#ABA590,0112/2///61987#ABB114,0112/2///61987#ABB115,0112/2///61987#ABB116,0112/2///61987#ABB992,0112/2///61987#ABA637,0112/2///61987#ABB117,0112/2///61987#ABB118,0112/2///61987#ABD004,0112/2///61987#ABC992,0112/2///61987#ABB120,0112/2///61987#ABB122,0112/2///61987#ABB121,0112/2///61987#ABA202,0112/2///61987#ABB994,0112/2///61987#ABB123,0112/2///61987#ABA901,0112/2///61987#ABB473,0112/2///61987#ABA935}

Version history3#

  1. Current rev 01
    28 Mar 2018 · 07:25 UTC by BATCH 00000762
    View on cdd.iec.ch ↗
  2. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.