Thermocouple input
properties characterizing an auxiliary thermocouple input
Hierarchy#
Ancestors (top) → ABC652 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties17#
@number of galvanic isolations
@number of cable specifications
style of electrical isolation of the thermocouple to the insert
greatest resistance that can be exhibited by the sensor connecting cable, if the device is to operate within the specified accuracy limits
classification of a thermocouple according to the material pair or standard type code
type of reference junction for a thermocouple
@number of electrical terminals
type of thermocouple assigned as default
lowest thermocouple input signal that the device can be adjusted to measure within the specified accuracy limits
highest thermocouple input signal that the device can be adjusted to measure within the specified accuracy limits
lower range end-value that has been configured at the factory
upper range end-value that has been configured at the factory
frequency characteristics of a line filter used to block interference
standard to which a thermocouple sensor type refers
reference to block ABC148
reference to block ABC220
reference to block ABC261
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-08-27
- Current version: 2013-08-27
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-08-27
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABC652
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-08-27
- MDC_P003_2
- 2013-08-27
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Thermoelementeingang
- MDC_P004.en
- Thermocouple input
- MDC_P004.fr
- Entrée de thermocouple
- MDC_P006.de
- Merkmale, die einen Thermoelement-Hilfseingang kennzeichnen
- MDC_P006.en
- properties characterizing an auxiliary thermocouple input
- MDC_P006.fr
- propriétés caractérisant une entrée à thermocouple auxiliaire
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB092,0112/2///61987#ABB173,0112/2///61987#ABB512,0112/2///61987#ABB174,0112/2///61987#ABB175,0112/2///61987#ABB176,0112/2///61987#ABB204,0112/2///61987#ABA411,0112/2///61987#ABB090,0112/2///61987#ABB093,0112/2///61987#ABB260,0112/2///61987#ABA387,0112/2///61987#ABC891,0112/2///61987#ABB103,0112/2///61987#ABC850,0112/2///61987#ABA401,0112/2///61987#ABC778}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.