Assigned flow velocity range
properties characterizing a range configured at the factory for flow velocity
Hierarchy#
Ancestors (top) → ABD493 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties4#
flow velocity value assigned to the lower range end-value of the input or output signal
flow velocity assigned to the upper range end-value of the input or output signal
difference between the upper and lower range value of flow velocity to which a flow velocity measurement instrument is adjusted
difference between the upper and lower range value of flow velocity to which a flow velocity measurement instrument is adjusted and calibrated
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 2
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00014- Dates
- Original: 2013-09-27
- Current version: 2014-03-13
- Current revision: 2014-06-18
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00014
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2014-03-13
- C019.de
- Mr. W. Hartmann
- C019.fr
- UTE
- MDC_P001_5
- 0112/2///61987#ABD493
- MDC_P002_1
- 1
- MDC_P002_2
- 2
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-27
- MDC_P003_2
- 2014-03-13
- MDC_P003_3
- 2014-06-18
- MDC_P004.de
- Eingestellter Bereich für Fließgeschwindigkeit
- MDC_P004.en
- Assigned flow velocity range
- MDC_P004.fr
- Étendue de vitesse d'écoulement assignée
- MDC_P006.de
- Merkmale, die den Bereich für Fließgeschwindigkeit kennzeichnen, konfiguriert im Herstellerwerk
- MDC_P006.en
- properties characterizing a range configured at the factory for flow velocity
- MDC_P006.fr
- propriétés caractérisant une étendue configurée en usine pour la vitesse d'écoulement
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD433,0112/2///61987#ABD434,0112/2///61987#ABD435,0112/2///61987#ABD436}
Version history2#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.