Design conditions for actuators
properties characterizing the values to be taken into account when designing an actuator for control valves other than process cases, environmental conditions and process conditions
Hierarchy#
Ancestors (top) → ABD843 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties21#
user requirement placed on the overall closing time of a control valve
user requirement placed on the overall closing time of an on/off valve
classification on a rotary actuator according to the direction of its action
classification on a linear actuator according to the direction of its action
factor by which the actuator of a final control element is oversized in the close position
factor by which the actuator of a final control element is oversized in the position between the open and the close
factor by which the actuator of a final control element is oversized in the open position
highest actuating force that a valve can bear without permanent damage
highest operating torque force that a valve can bear without permanent damage
highest number of valve openings/closings per unit time that an actuator can support
greatest required torque that has to be applied to a valve between its end positions
lowest actuating force to overcome the breakaway force of a valve
lowest actuating torque to overcome the breakaway force of a valve
@number of angular limit stops
@number of linear limit stops
user requirement placed on the overall opening time of a control valve
user requirement placed on the overall opening time of an on/off valve
classification of a control valve according to the travel and time behaviour close to the end position
classification of a manual override according to the method of power supply
reference to block ABD803
reference to block ABD832
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 3
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00009- Dates
- Original: 2013-09-02
- Current version: 2013-09-02
- Current revision: 2017-03-02
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00009
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-12
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABD843
- MDC_P002_1
- 1
- MDC_P002_2
- 3
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-02
- MDC_P003_2
- 2013-09-02
- MDC_P003_3
- 2017-03-02
- MDC_P004.de
- Auslegungsbedingungen für Antriebe
- MDC_P004.en
- Design conditions for actuators
- MDC_P006.de
- Merkmale, die die bei der Auslegung eines Stellantriebs für Stellventile zu berücksichtigenden Werte kennzeichnen, die keine Prozessfälle, Umweltbedingungen und Prozessbedingungen darstellen
- MDC_P006.en
- properties characterizing the values to be taken into account when designing an actuator for control valves other than process cases, environmental conditions and process conditions
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD583,0112/2///61987#ABD581,0112/2///61987#ABD582,0112/2///61987#ABD660,0112/2///61987#ABD620,0112/2///61987#ABD661,0112/2///61987#ABD642,0112/2///61987#ABD621,0112/2///61987#ABD574,0112/2///61987#ABD573,0112/2///61987#ABD670,0112/2///61987#ABE150,0112/2///61987#ABD667,0112/2///61987#ABE059,0112/2///61987#ABD554,0112/2///61987#ABD678,0112/2///61987#ABD553,0112/2///61987#ABD677,0112/2///61987#ABD630,0112/2///61987#ABD751,0112/2///61987#ABD758}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.