Explosion protection design approval [2]
properties characterizing an explosion protection design approval
Hierarchy#
Ancestors (top) → ABD868 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties16#
parts of a device to which the explosion protection approval applies and/or the area where a device or part can be installed
hazardous area dust group for which the device is designed to be used
level of protection assigned to a piece of equipment based on its risk of becoming a source of ignition in an explosive gas atmosphere, an explosive dust atmosphere or an explosive atmosphere that may exist in a coal mine
@number of device groups and categories
characters indicating the standard basis of an explosion protection design
set of specific measures applied to equipment to avoid ignition of a surrounding explosive atmosphere
classification system of electrical apparatus, based on its maximum surface temperature, related to the specific explosive atmosphere for which it is intended to be used
hazardous area zone for which the device is designed to be used
USA or Canadian hazardous area class for which the device is designed to be used
hazardous area dust group/explosion group for which the device is designed to be used
element of a hazardous area classification system in the USA and Canada indicating the likelihood of the existence of a classified hazard the place where the device can be installed
additional plain text on a name plate indicating conformance to a particular directive, standard or specification
maximum permissible surface temperature of a device used in an explosion hazardous area with combustible dust
alphanumeric character sequence identifying a single component or a component in a composite device
plain text describing a specific set of parameters of an explosion protection design approval
reference to block ABC190
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00004- Dates
- Original: 2013-09-02
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00004
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2014-12-12
- C018.fr
- 2013-11-24
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABD868
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-02
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Explosionsschutzausführung [2]
- MDC_P004.en
- Explosion protection design approval [2]
- MDC_P004.fr
- Agréments de conception de protection contre les explosions [2]
- MDC_P006.de
- Merkmale, die eine Zulassung für eine Explosionsschutzausführung kennzeichnen
- MDC_P006.en
- properties characterizing an explosion protection design approval
- MDC_P006.fr
- propriétés caractérisant un agrément de conception de protection contre les explosions
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB991,0112/2///61987#ABB385,0112/2///61987#ABB146,0112/2///61987#ABA462,0112/2///61987#ABA960,0112/2///61987#ABB013,0112/2///61987#ABA961,0112/2///61987#ABA463,0112/2///61987#ABA595,0112/2///61987#ABA464,0112/2///61987#ABA465,0112/2///61987#ABC820,0112/2///61987#ABA589,0112/2///61987#ABA593,0112/2///61987#ABB159,0112/2///61987#ABA468}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.