Normal process design conditions [3]
properties characterizing the normal range of process conditions for which a device shall be designed and operate within its specifications
Hierarchy#
Ancestors (top) → ABD948 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties22#
highest dynamic viscosity for which a device is or should be designed to operate within its specified limits
highest kinematic viscosity for which a device is or should be designed to operate within its specified limits
lowest fluid velocity for which a device is or should be designed to operate within its specified limits
highest fluid velocity for which a device is or should be designed to operate within its specified limits
states of the process material that the device is or should be designed to
highest rate of change of process temperature for which a device is or should be designed to operate within its specified limits
maximum permissible grain size of impurities for normal operation of a device
lowest process temperature for which a device is or should be designed to operate within its specified limits
highest process temperature for which a device is or should be designed to operate within its specified limits
lowest absolute pressure of a process for which a device is or should be designed to operate within its specified limits
highest absolute pressure of a process for which a device is or should be designed to operate within its specified limits
lowest gauge pressure of a process for which a device is or should be designed to operate within its specified limits
highest gauge pressure of a process for which a device is or should be designed to operate within its specified limits
lowest mass flow rate for which a device is or should be designed to operate within its specified limits
lowest actual flow rate for which a device is or should be designed to operate within its specified limits
lowest normalized flow rate for which a device is or should be designed to operate within its specified limits
highest mass flow rate for which a device is or should be designed to operate within its specified limits
highest actual volume flow rate for which a device is or should be designed to operate within its specified limits
highest normalized flow rate for which a device is or should be designed to operate within its specified limits
highest solids content expressed as mass fraction for which a device is or should be designed to operate within its specified limits
lowest differential pressure of a process for which a device is or should be designed to operate within its specified limits
highest differential pressure of a process for which a device is or should be designed to operate within its specified limits
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 3
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00019- Dates
- Original: 2013-09-02
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (25 keys from source .xls) — click to expand
- C002
- C00019
- C016
- Standard
- C017.de
- 0
- C017.fr
- 0
- C018.de
- 2015-01-14
- C018.fr
- 2015-01-14
- C019.de
- Mr. W. Hartmann
- C019.fr
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABD948
- MDC_P002_1
- 3
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-02
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Prozessauslegungsbedingungen (Normalbedingungen) [3]
- MDC_P004.en
- Normal process design conditions [3]
- MDC_P004.fr
- Conditions de conception de processus normales [3]
- MDC_P006.de
- Merkmale, die den Normalbereich der Prozessbedingungen kennzeichnen, für die ein Gerät auszulegen ist und innerhalb deren Spezifikationen es betrieben wird
- MDC_P006.en
- properties characterizing the normal range of process conditions for which a device shall be designed and operate within its specifications
- MDC_P006.fr
- propriétés caractérisant l’étendue normale de conditions de processus pour lesquelles un appareil doit être conçu et fonctionner dans ses spécifications
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABA954,0112/2///61987#ABB184,0112/2///61987#ABA955,0112/2///61987#ABB185,0112/2///61987#ABB997,0112/2///61987#ABB998,0112/2///61987#ABA918,0112/2///61987#ABA919,0112/2///61987#ABA598,0112/2///61987#ABB326,0112/2///61987#ABB327,0112/2///61987#ABB328,0112/2///61987#ABB329,0112/2///61987#ABB330,0112/2///61987#ABB331,0112/2///61987#ABA110,0112/2///61987#ABA111,0112/2///61987#ABA112,0112/2///61987#ABA114,0112/2///61987#ABB435,0112/2///61987#ABA642,0112/2///61987#ABA297}
Version history4#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.