Skip to content
OpenCDD
classITEM_CLASSv2rev 12016-05-02

Parameters of positioner

0112/2///61987#ABD963

properties characterizing the configuration of a positioner of a valve according to its specific values

Hierarchy#

Ancestors (top) → ABD963 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties28#

28 / 28
ABD551characteristic curveENUM_STRING_TYPE

characteristic of a signal or a physical output variable as response to a linear signal or physical input variable

ABD634maximum operating pressureREAL_MEASURE_TYPE

highest gauge pressure that can be applied or supplied to a device, so that it still operates within its specified limits

ABD656minimum operating pressureREAL_MEASURE_TYPE

lowest gauge pressure that can be applied or is supplied to a device, so that it still operates within its specified limits

ABD713split rangeENUM_STRING_TYPE

classification of a valve positioner parameter according to ability of the positioner to support a split range function

ABD766type of response configurationENUM_STRING_TYPE

classification of the configuration of system response to an input signal according to the kind of realization

ABH520type of step response testTRANSLATABLE_STRING_TYPE

classification of the step response test according to the kind of realization

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
2
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00009
Dates
  • Original: 2013-09-02
  • Current version: 2016-05-02
  • Current revision: 2016-05-02

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (20 keys from source .xls) — click to expand
C002
C00009
C016
Standard
C017.de
0
C018.de
2014-12-12
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABD963
MDC_P002_1
2
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2013-09-02
MDC_P003_2
2016-05-02
MDC_P003_3
2016-05-02
MDC_P004.de
Kennwerte des Stellungsreglers
MDC_P004.en
Parameters of positioner
MDC_P006.de
Merkmale, die die Eigenschaften eines Stellungsreglers gemäß dessen Kennwerten kennzeichnen
MDC_P006.en
properties characterizing the configuration of a positioner of a valve according to its specific values
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABD754,0112/2///61987#ABD551,0112/2///61987#ABD656,0112/2///61987#ABD634,0112/2///61987#ABD610,0112/2///61987#ABD788,0112/2///61987#ABD611,0112/2///61987#ABD789,0112/2///61987#ABD609,0112/2///61987#ABD787,0112/2///61987#ABD608,0112/2///61987#ABD786,0112/2///61987#ABD713,0112/2///61987#ABD557,0112/2///61987#ABD558,0112/2///61987#ABE225,0112/2///61987#ABD721,0112/2///61987#ABD766,0112/2///61987#ABH520,0112/2///61987#ABH521,0112/2///61987#ABH522,0112/2///61987#ABD679,0112/2///61987#ABD723,0112/2///61987#ABD555,0112/2///61987#ABD720,0112/2///61987#ABD757,0112/2///61987#ABD599,0112/2///61987#ABD775}

Version history3#

  1. Current rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    View on cdd.iec.ch ↗
  2. superseded rev 02
    18 Jun 2014 · 13:34 UTC by BATCH 00000701
    ↓ Version JSON
    View on cdd.iec.ch ↗
  3. superseded rev 01
    08 Apr 2014 · 17:24 UTC by BATCH 00000699
    ↓ Version JSON
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.