Process conditions at the outlet
properties characterizing the range of process conditions at the outflow of a device
Hierarchy#
Ancestors (top) → ABD989 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties21#
alphanumeric character sequence uniquely identifying a process material
name or chemical formula of a process material
for a physical system exchanging quantities of heat with two bodies, during a reversible cycle, a positive state quantity characterizing each body and proportional to the quantity of heat exchanged with this body
pressure using absolute vacuum as the datum point
pressure using atmospheric pressure as the datum point
plain text characterizing a process stream
mass of material flowing per unit time
actual volume of fluid that passes a given point per unit time
volume of material flowing per unit time calculated to base conditions
alphanumeric character sequence uniquely identifying a process stream
name of a process stream
ratio of the mass of the gases to the mass sum of all constituents the fluid
ratio of the mass of the liquids to the mass sum of all constituents the fluid
flow direction through a device referred to the intended direction under the given process conditions
ratio of the mass of the solids to the mass sum of all constituents the fluid
classification of a fluid phase according to its state
ratio of the mass of the vapors to the mass sum of all constituents the fluid
reference to block ABD881
reference to block ABD833
reference to block ABD955
reference to block ABE045
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00009- Dates
- Original: 2013-09-02
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00009
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-12
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABD989
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-02
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Prozessbedingungen am Ausgang
- MDC_P004.en
- Process conditions at the outlet
- MDC_P006.de
- Merkmale, die den Bereich der Prozessbedingungen an der Ausgangsseite eines Geräts kennzeichnen
- MDC_P006.en
- properties characterizing the range of process conditions at the outflow of a device
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABB376,0112/2///61987#ABB377,0112/2///61987#ABB288,0112/2///61987#ABA580,0112/2///61987#ABA622,0112/2///61987#ABB181,0112/2///61987#ABB182,0112/2///61987#ABA927,0112/2///61987#ABB290,0112/2///61987#ABB291,0112/2///61987#ABB292,0112/2///61987#ABD680,0112/2///61987#ABD753,0112/2///61987#ABD595,0112/2///61987#ABD790,0112/2///61987#ABD605,0112/2///61987#ABD709,0112/2///61987#ABE151,0112/2///61987#ABE301,0112/2///61987#ABE125,0112/2///61987#ABE211}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.