Structural design of a positioner
properties characterizing the constructional details of a positioner
Hierarchy#
Ancestors (top) → ABE034 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties27#
ability to set a device to perform a particular type of action
highest gauge pressure that can be applied to a single acting actuator, so that it still operates within its specified limits
highest gauge pressure that can be supplied to a single acting actuator, so that it still operates within its specified limits
highest amount of fluid that can be output by a positioner connected to an actuator with a diaphragm or a single acting cylinder, expressed as normalized volume flow at a given supply pressure
highest amount of fluid that can be output by a positioner connected to an actuator with a double acting cylinder, expressed as normalized volume flow at a given supply pressure
lowest gauge pressure that can be applied to a double acting actuator, so that it still operates within its specified limits
lowest gauge pressure that can be applied to a single acting actuator, so that it still operates within its specified limits
number of limit switches that are integrated into a device
number of events that can be stored in a device
supply pressure at which the output capacity of a positioner was determined
design of a device that goes beyond the standard design
time duration for which measurement data are stored within a device
time duration for which opening percentage values are stored within a device
classification of a positioner according to way in which the action is applied
output change to a given input signal
classification of a positioner according to the actuator for which it can be used
classification of a device according to the method used to measure deviations of the system from the expected behaviour
classification of limit switches that are integrated into a device according to their functional design
classification of a positioner according to its functional design
classification of a supply pressure measurement according to the component used to measure the pressure
classification of a device according to the diagnostic functions it provides
classification of a valve assembly according to the status information it provides during operation
classification of a positioner according to the method by which it is mounted on a valve or actuator or a standard describing the mounting method
classification of a pressure gauge according to the variable it indicates
classification of a bypass manifold according to the number of gauges mounted
value to which the auto adjust function is adjusted
classification of a device regarding automatically setting of the parameters needed for its function
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 2
- Revision
- 1
- Status
- Standard
- Responsible committee
- SC65E – IEC 61987
- Change request
C00009- Dates
- Original: 2013-09-02
- Current version: 2016-05-02
- Current revision: 2016-05-02
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (20 keys from source .xls) — click to expand
- C002
- C00009
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-12
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE034
- MDC_P002_1
- 2
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2013-09-02
- MDC_P003_2
- 2016-05-02
- MDC_P003_3
- 2016-05-02
- MDC_P004.de
- Konstruktiver Aufbau eines Stellungsreglers
- MDC_P004.en
- Structural design of a positioner
- MDC_P006.de
- Merkmale, die die konstruktiven Details eines Stellungsreglers kennzeichnen
- MDC_P006.en
- properties characterizing the constructional details of a positioner
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD763,0112/2///61987#ABD726,0112/2///61987#ABD556,0112/2///61987#ABD740,0112/2///61987#ABD742,0112/2///61987#ABD783,0112/2///61987#ABD711,0112/2///61987#ABD784,0112/2///61987#ABD639,0112/2///61987#ABD640,0112/2///61987#ABD704,0112/2///61987#ABD658,0112/2///61987#ABD636,0112/2///61987#ABD657,0112/2///61987#ABD635,0112/2///61987#ABD692,0112/2///61987#ABD755,0112/2///61987#ABD694,0112/2///61987#ABD746,0112/2///61987#ABD781,0112/2///61987#ABD774,0112/2///61987#ABD782,0112/2///61987#ABH524,0112/2///61987#ABH523,0112/2///61987#ABD715,0112/2///61987#ABD716,0112/2///61987#ABE381}
Version history3#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.