Parameters of filter regulator
properties characterizing the configuration of a filter regulator according to its specific values
Hierarchy#
Ancestors (top) → ABE560 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.
Higher level classes3#
Declared properties10#
highest gauge pressure value at the device inlet to which a pressure reducing regulator or a back pressure regulator can be adjusted and still remain within the specified performance limits
highest gauge pressure value at the device outlet to which a pressure reducing regulator or a back pressure regulator can be adjusted and still remain within the specified performance limits
lowest gauge pressure value at the device inlet to which a pressure reducing regulator or a back pressure regulator can be adjusted and still remain within the specified performance limits
lowest gauge pressure value at the device outlet to which a pressure reducing regulator or a back pressure regulator can be adjusted and still remain within the specified performance limits
rated flow coefficient, that is expressed by a manufacturer specific designation
number of US gallons of water, within a temperature range of 40°F to 100°F, that will flow through a valve in 1 min when a pressure drop of 1 psi exists
volumetric flow rate of water in cubic metres per hour (capacity) through a valve at a rated travel at the static pressure loss across the valve of 100 kPa (1 bar), within a temperature range of 278 K to 313 K (5°C to 40°C)
gauge pressure value at the device outlet to which a pressure reducing regulator or a back pressure regulator is adjusted
flow through a valve at a given reference gauge inlet pressure and zero gauge outlet pressure
gauge inlet pressure for stating a flow value
Subclasses#
No subclasses
This class is a leaf — no other classes inherit from it.
Metadata#
- Version
- 1
- Revision
- 1
- Status
- Standard
- Publisher
- IEC
- Published in
- IEC 61987
- Responsible committee
- SC65E – IEC 61987
- Change request
C00016- Dates
- Original: 2014-07-25
- Current version: 2018-03-20
- Current revision: 2018-03-20
Full source data#
Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.
Raw properties (22 keys from source .xls) — click to expand
- C002
- C00016
- C011
- IEC
- C012
- IEC 61987
- C016
- Standard
- C017.de
- 0
- C018.de
- 2014-12-12
- C019.de
- Mr. W. Hartmann
- MDC_P001_5
- 0112/2///61987#ABE560
- MDC_P002_1
- 1
- MDC_P002_2
- 1
- MDC_P003_0
- 2018-03-28
- MDC_P003_1
- 2014-07-25
- MDC_P003_2
- 2018-03-20
- MDC_P003_3
- 2018-03-20
- MDC_P004.de
- Kennwerte des Filterreglers
- MDC_P004.en
- Parameters of filter regulator
- MDC_P006.de
- Merkmale, die die Eigenschaften eines Filterreglers gemäß dessen Kennwerten kennzeichnen
- MDC_P006.en
- properties characterizing the configuration of a filter regulator according to its specific values
- MDC_P010
- 0112/2///61987#ABV501
- MDC_P011
- ITEM_CLASS
- MDC_P012
- SC65E – IEC 61987
- MDC_P014
- {0112/2///61987#ABD696,0112/2///61987#ABD695,0112/2///61987#ABD666,0112/2///61987#ABD655,0112/2///61987#ABD631,0112/2///61987#ABD659,0112/2///61987#ABD638,0112/2///61987#ABD708,0112/2///61987#ABE379,0112/2///61987#ABE380}
Version history1#
IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.