Skip to content
OpenCDD
classITEM_CLASSv1rev 12018-03-20

Parameters of restriction orifice/diffuser

0112/2///61987#ABE562

properties characterizing the configuration of a restriction orifice or diffuser according to its specific values

Hierarchy#

Ancestors (top) → ABE562 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties18#

18 / 18
ABA324base densityREAL_MEASURE_TYPE

density used to calculate variables to reference conditions

ABA326base dynamic viscosityREAL_MEASURE_TYPE

dynamic viscosity used to calculate variables to reference conditions

ABA328base absolute pressureREAL_MEASURE_TYPE

absolute pressure used to calculate variables to reference conditions

ABA330base gauge pressureREAL_MEASURE_TYPE

gauge pressure used to calculate variables to reference conditions

ABB271tag nameNON_TRANSLATABLE_STRING_TYPE

alphanumeric character sequence uniquely identifying a measuring or control point

ABB290mass flow rateREAL_MEASURE_TYPE

mass of material flowing per unit time

ABB781base temperatureREAL_MEASURE_TYPE

temperature used to calculate variables to reference conditions

ABD695rated flow coefficient CvREAL_MEASURE_TYPE

number of US gallons of water, within a temperature range of 40°F to 100°F, that will flow through a valve in 1 min when a pressure drop of 1 psi exists

ABD696rated flow coefficient KvsREAL_MEASURE_TYPE

volumetric flow rate of water in cubic metres per hour (capacity) through a valve at a rated travel at the static pressure loss across the valve of 100 kPa (1 bar), within a temperature range of 278 K to 313 K (5°C to 40°C)

ABH519phase of matterENUM_STRING_TYPE

state of a medium distinguishable by its physical properties from other states of the same or other media

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Publisher
IEC
Published in
IEC 61987
Responsible committee
SC65E – IEC 61987
Change request
C00016
Dates
  • Original: 2014-07-25
  • Current version: 2018-03-20
  • Current revision: 2018-03-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (22 keys from source .xls) — click to expand
C002
C00016
C011
IEC
C012
IEC 61987
C016
Standard
C017.de
0
C018.de
2014-12-12
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABE562
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_1
2014-07-25
MDC_P003_2
2018-03-20
MDC_P003_3
2018-03-20
MDC_P004.de
Kennwerte der Begrenzungsblende/des Diffusers
MDC_P004.en
Parameters of restriction orifice/diffuser
MDC_P006.de
Merkmale, die die Eigenschaften einer Begrenzungsblende oder eines Diffusers gemäß deren Kennwerten kennzeichnen
MDC_P006.en
properties characterizing the configuration of a restriction orifice or diffuser according to its specific values
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABB271,0112/2///61987#ABD696,0112/2///61987#ABD695,0112/2///61987#ABD666,0112/2///61987#ABE667,0112/2///61987#ABE668,0112/2///61987#ABE669,0112/2///61987#ABB290,0112/2///61987#ABB291,0112/2///61987#ABA324,0112/2///61987#ABA326,0112/2///61987#ABA327,0112/2///61987#ABH430,0112/2///61987#ABA328,0112/2///61987#ABA330,0112/2///61987#ABB781,0112/2///61987#ABH519,0112/2///61987#ABB332}

Version history1#

  1. Current rev 01
    28 Mar 2018 · 07:26 UTC by BATCH 00000762
    View on cdd.iec.ch ↗

IEC CDD records every published revision of each entity — version number, status, timestamp, and the change request that introduced it. OpenCDD captures the full chain of custody from cdd.iec.ch; the entry marked Current is the one rendered on this page.