Calculation results of flow modification accessory

0112/2///61987#ABE658

properties stating results of design calculations for flow modification accessories resulting from the given process conditions

Hierarchy#

Ancestors (top) → ABE658 (highlighted) → subclasses and powertype instances. Capped at 12 each; see the full lists in the sections below.

Higher level classes3#

Declared properties15#

15 / 15
ABA949Reynolds numberREAL_MEASURE_TYPE

characteristic number derived from the quotient of inertial forces and viscous forces of a fluid

ABD545calculated flow coefficient CvREAL_MEASURE_TYPE

calculation result for the flow coefficient Cv resulting from the given process conditions not taking into account the pressure loss of a pipe reduction at the inlet or outlet

ABD546calculated flow coefficient Fp CvREAL_MEASURE_TYPE

calculation result for the flow coefficient Kv resulting from the given process conditions taking into account the pressure loss of a pipe reduction at the inlet or outlet

ABD547calculated flow coefficient Fp KvREAL_MEASURE_TYPE

calculation result for the flow coefficient Kv resulting from the given process conditions taking into account the pressure loss of a pipe reduction at the inlet or outlet

ABD548calculated flow coefficient KvREAL_MEASURE_TYPE

calculation result for the flow coefficient Kv resulting from the given process conditions not taking into account the pressure loss of a pipe reduction at the inlet or outlet

ABD685piping geometry factor FpREAL_MEASURE_TYPE

ratio of the flow rate through a control valve installed with attached fittings to the flow rate that would result if the control valve was installed without attached fittings and tested under identical conditions which will not produce choked flow in either installation

ABD710sound pressure levelREAL_MEASURE_TYPE

logarithmical measure of the pressure of a sound wave relative to a reference level

Subclasses#

No subclasses

This class is a leaf — no other classes inherit from it.

Metadata#

Version
1
Revision
1
Status
Standard
Responsible committee
SC65E – IEC 61987
Change request
C00016
Dates
  • Current version: 2018-03-20
  • Current revision: 2018-03-20

Full source data#

Every key from the original .xls export, including multilingual variants, status, publisher, committee, and workbook-specific codes.

Raw properties (19 keys from source .xls) — click to expand
C002
C00016
C016
Standard
C017.de
0
C018.de
2014-12-12
C019.de
Mr. W. Hartmann
MDC_P001_5
0112/2///61987#ABE658
MDC_P002_1
1
MDC_P002_2
1
MDC_P003_0
2018-03-28
MDC_P003_2
2018-03-20
MDC_P003_3
2018-03-20
MDC_P004.de
Berechnungsergebnisse für Zubehör zur Durchflussmodifizierung
MDC_P004.en
Calculation results of flow modification accessory
MDC_P006.de
Merkmale, die die Ergebnisse von Auslegungsberechnungen für Zubehörteile zur Durchflussmodifizierung anhand der gegebenen Prozessbedingungen kennzeichnen
MDC_P006.en
properties stating results of design calculations for flow modification accessories resulting from the given process conditions
MDC_P010
0112/2///61987#ABV501
MDC_P011
ITEM_CLASS
MDC_P012
SC65E – IEC 61987
MDC_P014
{0112/2///61987#ABD548,0112/2///61987#ABD545,0112/2///61987#ABD547,0112/2///61987#ABD546,0112/2///61987#ABD685,0112/2///61987#ABE667,0112/2///61987#ABE668,0112/2///61987#ABE669,0112/2///61987#ABD710,0112/2///61987#ABD701,0112/2///61987#ABA949,0112/2///61987#ABD598,0112/2///61987#ABD681,0112/2///61987#ABB066,0112/2///61987#ABD549}